Assessment of MRI issues at 1.5 T for the Temperature Logger Implant
Omeed Mahrouyan1, Øivind Tøien2, Frank G Shellock3
1Department of Biology, Loyola Marymount University, 1 Loyola Marymount University Dr., Los Angeles, CA 90045, United States.
Purpose:
The Temperature Logger Implant is a newly developed device that is capable of providing data for animal studies on thermoregulatory function, hibernation, hypothermia, and general health. During research, it may be necessary to conduct a magnetic resonance imaging (MRI) examination on an animal with this device implanted to assess anatomical changes or other conditions. Notably, this new device was specially designed to be unaffected by the electromagnetic fields used for MRI. Therefore, to verify that there would be no problems related to MRI, the purpose of this investigation was to evaluate MRI-related issues for the Temperature Logger Implant.
Methods:
Tests were performed on the Temperature Logger Implant using well-accepted techniques to evaluate magnetic field interactions (translational attraction and torque, 1.5 T), MRI-related heating (whole body averaged specific absorption rate, 2.9 W/kg), artifacts (T1-weighted, spin echo and gradient echo pulse sequences), and functional changes related to exposure to eight different imaging conditions.
Results:
Magnetic field interactions were relatively low (deflection angle 4°, no torque) and heating was minor (highest temperature rise, > 1.1 °C) indicating that these factors will not pose a hazard to an animal. The largest artifact (gradient echo pulse sequence) extended 10 mm from the size and shape of the Temperature Logger Implant. Exposure to the eight different conditions at 1.5 T/ 64 MHz did not alter or damage the operational aspects of the device.
Conclusions:
The findings demonstrated that MRI can be performed safely on an animal with this new Temperature Logger Implant and, thus, this device is deemed "MR Conditional" (i.e., using current labeling terminology), according to the conditions used in this investigation.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Ethical Issues
Ethical Concerns in Healthcare:
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...