Type 2 diabetes detection based on serum sample Raman spectroscopy
J L González-Solís1, J R Villafan-Bernal2, B E Martínez-Zérega3
1Biophysics and Biomedical Sciences Laboratory, Centro Universitario de los Lagos, Universidad de Guadalajara, Enrique Díaz de León 1144, Paseo de la Montaña, CP 47460, Lagos de Moreno, Jalisco, México. jluis@culagos.udg.mx.
Abstract:
In this work, we propose to the Raman spectroscopy as a new technique for the detection of the type 2 diabetes using blood serum samples. The serum samples were obtained from 15 patients who were clinically diagnosed with type 2 diabetes mellitus and 20 healthy volunteers. The average spectra showed equally intense peaks as, 695 cm-1, the doublet of tyrosine at 828 and 853 cm-1, phenylalanine at 1002 and 1028 cm-1, the phospholipid shoulder at 1300-1345 cm-1, and proteins (amide I) at 1654 cm-1. The major differences were found at 661 and 1404 cm-1 (glutathione), 714 (polysaccharides), 605 (Phe), 545 cm-1 (tryptophan), and the shoulder of amide III at 1230-1282 cm-1, where seem to disappear in the diabetes spectrum. On the contrary, the region that is more highlighted due to that diabetes peaks are clearly more intense was 897-955 cm-1. Principal component analysis and linear discriminate analysis were employed for developing discrimination method. The first three principal components provided a classification of the samples from healthy and diabetes patients with high sensitivity and specificity. In addition, when the first principal component was plotted as a function of the Raman shift, it revealed these shifts accounted for the greatest differences between control and diabetes samples, which coincided with the shifts of spectral differences shown by mean spectra. Our results demonstrated that serum sample Raman spectroscopy promises to become a non-invasive support tool of the currently applied techniques for type 2 diabetes detection, decreasing the false-positive cases.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...