Related Experiment Video
Updated: Feb 10, 2026

A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
A preliminary study of photoacoustic/ultrasound dual-mode imaging in melanoma using MAGE-targeted gold nanoparticles
Xuelin Li1, Dong Wang2, Haitao Ran1
1Institute of Ultrasound ImagingofChongqing Medical University, Chongqing Key Laboratory of Ultrasound Molecular Imaging, Chongqing, 400010, China.
Abstract:
Nanoprobes are small enough to circulate within the vasculature and can reach tumour tissues through the endothelial gap, providing a new strategy for accurate tumour monitoring and imaging-guided antitumour therapy at the molecular level. Both photoacoustic and ultrasonic imaging are noninvasive tools for cancer detection via the application of nanoprobes. In this study, a polymeric multifunctional nanoparticle probe loaded with gold nanorods (Au-NRs) and liquid perfluorocarbon (perfluorinated hexane/PFH) and conjugated to a monoclonal antibody (MAGE-1 antibody) to melanoma-associated antigens (MAGE) targeting melanoma was successfully prepared by the double emulsion and carbodiimide methods as a targeted photoacoustic/ultrasound dual-mode imaging contrast agent (MAGE-Au-PFH-NPs). Cell-targeting experiments in vitro showed large amounts of MAGE-Au-PFH-NPs surrounding B16 melanoma cells in the targeted group. The photoacoustic signal in the targeted group was significantly increased, and the duration was longer than that in the untargeted group in vivo. The photoacoustic signal of the nanoprobes was enhanced with increased Au-NR concentration in the photoacoustic experiment in vitro. The enhanced signal was observed by ultrasound after 808-nm laser irradiation. A cytotoxicity and biocompatibility test showed that MAGE-Au-PFH-NPs exhibited good biological safety. The MAGE-Au-PFH-NPs can be used as a photoacoustic/ultrasound dual-mode contrast agent to lay the foundation for a promising new approach for the noninvasive targeting, monitoring and treatment of tumours.
Related Concept Videos
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
MOSFET: Enhancement Mode
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...

