Related Experiment Video
Updated: Feb 10, 2026

Glass Wool Filters for Concentrating Waterborne Viruses and Agricultural Zoonotic Pathogens
Published on: March 3, 2012
Reducing phosphorus (P) losses from drained agricultural fields with iron coated sand (- glauconite) filters
Stany Vandermoere1, Njaka Andriamanantena Ralaizafisoloarivony1, Eric Van Ranst2
1Department of Soil Management, Faculty of Bio-Science Engineering, Ghent University, Coupure Links 653, 9000 Ghent, Belgium.
Abstract:
In north-west Europe, agricultural diffuse P losses are a major cause of eutrophication problems in surface waters. Given that the Water Framework Directive (WFD) demands fast water quality improvements and most of the actual P mitigation strategies tend to work on the long run, new short-term mitigation measures are urgently needed. We here report on the entire process of developing small scale field filters to remove P at the end of tile drains, starting from the screening of potential P sorbing materials (PSM): iron coated sand (ICS), acid pre-treated natural minerals (biotite, glauconite and olivine) and bauxite. Initial batch (ad)sorption experiments revealed following order in both, P sorption capacity and speed: ICS > bauxite > glauconite > olivine = biotite. Because of the presence of significant amounts of lead and/or nickel, we excluded bauxite and olivine from further experiments. Subsequent lab scale flow through systems were conducted with P filters containing mixtures of ICS and glauconite (100/0, 90/10, 80/20, 70/30 and 60/40%, respectively, on weight basis). We found a significant relationship between Ksat and the filter mixtures particle size distribution and bulk density, and a significant effect of the filter mixture composition on P removal efficiency and stability of Ksat. During the 10 week field trials, the pure ICS filters were capable of processing all drainage discharge rates (up to 6 m3 day-1) with a P removal efficiency of ≥74%. The 90/10 ICS/glauconite filters could process up to 4 m3 water day-1 with a P removal efficiency of 57%. As saturated ICS filters can easily be replaced and recycled for other applications, this is a promising sustainable technique to drastically cut back diffuse P losses and to tremendously improve surface water quality in the short term.
Related Concept Videos
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Adaptations that Reduce Water Loss
The Phosphorus Cycle
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Active Filters

