Related Experiment Video
Updated: Feb 10, 2026

Author Spotlight: Implementing the Enhanced Recovery After Surgery Concept in Rehabilitation Following Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
Use of the 5-Strand Hamstring Autograft Technique in Increasing Graft Size in Anterior Cruciate Ligament
Lingaraj Krishna1, Taufiq Panjwani1, Ying Ren Mok1
1National University Hospital Sports Centre, Department of Orthopaedic Surgery, National University Health System, Singapore.
Background:
To determine the extent to which a strategy of routinely preparing a 5-strand hamstring autograft would increase graft size in anterior cruciate ligament (ACL) reconstruction.
Methods:
A total of 64 patients were enrolled in a prospective randomized controlled study comparing 5-strand and quadrupled semitendinosus-gracilis autografts in single-bundle ACL reconstruction (5-strand group, n = 32; 4-strand group, n = 32). In the 5-strand group, the diameter of the 4-strand construct and the subsequent 5-strand graft used were measured, whereas in the 4-strand group, the diameter of the quadrupled graft used was measured. Quadrupled graft diameter and hamstring tendon lengths were correlated with patient gender, height, weight, and body mass index (BMI).
Results:
The mean diameter of the final graft used in the 5-strand group was 8.8 ± 0.8 mm, whereas that in the 4-strand group was 7.8 ± 0.7 mm (P < .001). The mean increase in graft size achieved with the use of the 5-strand technique was 1.4 ± 0.3 mm. In the 5-strand group, 24 of 32 (75%) patients had graft diameters exceeding 8 mm compared with 9 of 32 (28%) patients in the 4-strand group (P < .001). Quadrupled graft diameter was significantly correlated with patient height and BMI, whereas the gracilis and semitendinosus lengths were significantly correlated with patient height.
Conclusions:
The 5-strand hamstring autograft provides a significantly larger diameter graft compared with the quadrupled hamstring autograft in ACL reconstruction. Graft sizes exceeding 8 mm are achievable in 75% of patients with the routine application of this technique. This is significantly more than that obtained with the standard quadrupled hamstring graft. Hamstring tendon length and quadrupled hamstring graft diameter are also significantly correlated with patient height.
Level Of Evidence:
Level 1, prospective randomized controlled trial.
More Related Videos
10:32Athymic Rat Model for Evaluation of Engineered Anterior Cruciate Ligament Grafts
Published on: March 26, 2015
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Lagging Strand Synthesis
There are several major differences between synthesis of the leading strand and synthesis of the lagging strand. 1) Leading strand synthesis happens in the direction of replication fork opening, whereas lagging strand synthesis happens in the...
Lagging Strand Synthesis
Fixing Double-strand Breaks
Fixing Double-strand Breaks
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Increasing Function