Related Experiment Video
Updated: Feb 10, 2026

Fabrication and Operation of a Nano-Optical Conveyor Belt
Published on: August 26, 2015
Pulsed operation of a miniature scalar optically pumped magnetometer
Vladislav Gerginov1,2, Sean Krzyzewski2, Svenja Knappe2,3
1Time and Frequency Division, National Institute of Standards and Technology (NIST), 325 Broadway, Boulder, Colorado 80305, USA.
Abstract:
A scalar magnetic field sensor based on a millimeter-size 87Rb vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell-Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
Related Concept Videos
Scalar Notation
Consider a man pulling a rope from a hook in the northeast direction. The...
Scalar and Vectors
Scalar quantities with the same physical units can be added or subtracted according to the usual algebra rules for numbers. For example, a class ending 10 min earlier than 50 min lasts...
Introduction to Scalars
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...