Objective:
To discuss the effectiveness of posterior short-segment fixation including the fractured vertebra for severe unstable thoracolumbar fractures using pedicle screw fixation.
Methods:
Between May 2008 and July 2013, 52 patients of severe unstable thoracolumbar fractures were treated through posterior short-segment fixation including the fractured vertebra using pedicle screw fixation. There were 33 males and 19 females with an age of 21-56 years (mean, 37.9 years). The causes of thoracolumbar burst fractures included fall from height in 32 cases, traffic accidents in 16 cases, and others in 4 cases. The load sharing classification (LSC) score was 7-9 (mean, 7.85). The levels involved included T 11 in 4 cases, T 12 in 19 cases, L 1 in 25 cases, and L 2 in 4 cases. According to Frankel classification, there were 2 cases of grade A, 4 cases of grade B, 8 cases of grade C, 11 cases of grade D, and 27 cases of grade E. The rate of spinal canal occupying was 24.2%-76.7% (mean, 47.1%). The time from injury to operation was 3-5 days (mean, 3.6 days). The effectiveness was assessed by the changes of injured vertebral Cobb angle, anterior vertebral height, and the Frankel grading at pre- and post-operation.
Results:
The operation time was 85-127 minutes (mean, 106.5 minutes). The intraoperative blood loss was 90-155 mL (mean, 137.6 mL). All the incision healed at first intension. Forty-seven patients were followed up 19-27 months (mean, 23.2 months), and no incision infection, screw loosening, or other internal fixation failures was found during follow-up. The injured vertebral Cobb angle and anterior vertebral height at immediate after operation or at last follow-up were significantly improved when compared with preoperative values ( P<0.001). There was a loss of injured vertebral Cobb angle and anterior vertebral height at last follow-up, but no significant difference was found between at immediate after operation and at last follow-up ( P>0.05). The Frankel grade improved by 0-2 grades at last follow-up, showing significant difference when compared with preoperative grades ( Z=15.980, P=0.003).
Conclusion:
Posterior short-segment fixation including the fractured vertebra for severe unstable thoracolumbar fractures (LSC≥7) using pedicle screw fixation can correct the kyphosis deformity, restore vertebral body height, and aviod the need of anterior reconstruction.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
General Structure of a Vertebra
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Short-distance Transport of Resources
Carbon-dioxide Fixation
Power System Three-Phase Short Circuits