Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Double-tiered subchondral support fixation with optimal distal dorsal cortical distance using a variable-angle volar
Sang Ki Lee1, Young Sub Chun1, Hyun Min Shin1
1Eulji University College of Medicine, Orthopedic Surgery, 1306 Dunsan-dong, 35233 Seo-gu Daejeon, Daejeon Korea, Republic of Korea.
Background:
Double-tiered subchondral support (DSS) procedures with optimal distal dorsal cortical distance (DDD) have been reported to be effective in treating distal radius fractures, but there have been no studies of osteoporotic distal radius fractures in elderly patients. In this study, we demonstrated the efficacy of the DSS procedure with optimal DDD using a variable-angle volar locking-plate system for the treatment of osteoporotic distal radius fractures in elderly patients.
Methods:
One hundred and twenty-two patients (mean age, 73.3 years; age range, 65-88 years) with distal radius fracture were treated using a variable-angle volar locking-plate system with DSS. Patients were divided into DSS and non-DSS groups based on postoperative and 12-month follow-up radiographs, and radiological and clinical assessment was performed. Finally, we divided all 122 patients into two groups based on volar tilt of 6° on 12-month follow-up radiographs, and postoperative DDD values were compared.
Results:
Volar tilt decreased (p=0.02), and ulnar variance increased (p=0.01) more in the non-DSS group. The non-DSS group showed a significant correlation between postoperative DDD value and change in DDD value (p=0.00). The mean postoperative DDDs in the group with final volar tilt<6° and in the group with final volar tilt≥6° were 6.4mm (SD±1.7mm) and 4.6mm (SD±1.4mm) respectively (p=0.02). At 4-month follow-up, pronation (p=0.05) and supination (p=0.04) were improved, and at 12-month follow-up, supination (p=0.05) was improved in the DSS group.
Conclusion:
The use of the DSS procedure and reduction of DDD to 4.6mm or less using a variable-angle volar locking-plate system was effective in maintaining anatomical reduction for the treatment of osteoporotic distal radius fractures in elderly patients.
Level Of Evidence:
III Therapeutic study.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Related Concept Videos
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Radius of Gyration of an Area
Distance Problem
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
The Distance Formula
Distance Corrections