Statement Of Problem:
Rapid prototyping, including stereolithography (SLA), is a more recent technique for fabricating metal frameworks than the conventional lost-wax technique. However, investigations of the marginal discrepancies and internal spacing of cobalt-chromium (Co-Cr) metal copings fabricated using SLA are lacking.
Purpose:
The purpose of this in vitro study was to evaluate the clinical acceptability of the marginal discrepancies and internal spacing of Co-Cr metal copings fabricated using the SLA technique.
Material And Methods:
A resin tooth of a maxillary right first premolar was prepared with a deep chamfer margin for a metal-ceramic crown. Titanium master dies were milled after scanning the prepared tooth (n=45). In conventional lost wax group (group LW), the conventional lost-wax technique was used to fabricate Co-Cr metal copings (n=15). In milling group (group MC), a computer-aided design (CAD) system was used to design the metal copings, which were milled from Co-Cr alloy (n=15). The CAD system was also used to design the metal copings in a 3D-printed group (group SL), and Co-Cr metal copings were cast from resin patterns fabricated using the SLA device (n=15). Marginal discrepancies and internal spaces were measured using an optical microscope at ×100 magnification at 11 reference points. The values were analyzed statistically with 1-way analysis of variance (α=.05).
Results:
The mean (±SD) overall space was 63.2 ±16.6 μm for group LW, 70.2 ±15.5 μm for group SL, and 130.3 ±13.8 μm for group MC. The overall spaces differed significantly between group MC and the other 2 groups (P<.05). The marginal discrepancy and internal spaces were significantly larger in group MC than in groups LW and SL. (P<.05). Occlusal spaces differed significantly among the 3 study groups (P<.05).
Conclusions:
Co-Cr metal copings fabricated using an SLA technique showed clinically acceptable marginal discrepancies and internal spaces. These spaces did not differ significantly from those obtained with the conventional lost-wax technique.
Related Concept Videos
Induced-fit Model
Enzymes exhibit substrate specificity, meaning that they can only bind to certain substrates. This is mainly determined by the shape and chemical...
Inclusive Fitness
Goodness-of-Fit Test
Coping Strategies: Problem Focused
For example, consider a student who struggles to understand their...
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....