Purpose:
The purpose of this study was to evaluate the efficacy of 360-degree suture trabeculotomy (360S-LOT) ab interno for treating open-angle glaucoma (OAG). Risk factors of surgical failure were examined.
Patients And Methods:
360S-LOT ab interno alone was performed for patients with uncontrolled OAG, and combined 360S-LOT ab interno/phacoemulsification was performed for patients with controlled OAG with a visually significant cataract between March 2014 and September 2015 at a single center. The patients were prospectively followed for 2 years. The main outcome measures included 2-year intraocular pressure (IOP), number of anti-glaucoma medications used, postoperative complications, and predictive factors of surgical failure. Kaplan-Meier analysis was performed, with surgical success (with or without medication use) defined as postoperative IOP ≤15 mmHg and IOP reduction ≥20% (criterion A) or IOP ≤12 mmHg and IOP reduction ≥30% (criterion B). Predictive factors were evaluated using Cox proportional hazard ratios.
Results:
A total of 64 eyes of 64 patients were included, and 50 (78%) eyes of 64 eyes underwent a phacoemulsification combination procedure. Surgery significantly reduced IOP from 18.4 ± 2.9 mmHg before surgery to 13.4 ± 3.0 mmHg after surgery (P < 0.001). Patients used an average of 1.8 ± 1.5 medications before surgery and 1.3 ± 1.5 medications after surgery (P = 0.101). No serious postoperative complications were observed. The probability of surgical success was 49.2% and 16.0% using criteria A and B, respectively. No risk factors of surgical failure were identified.
Conclusion:
The 360S-LOT ab interno procedure is a favorable option for treating eyes with mild or moderate OAG.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
One-Degree-of-Freedom System
A one-degree-of-freedom system is defined by an independent variable that determines its state and behavior. One example of a one-degree-of-freedom system is a simple harmonic oscillator, such as a...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Degree of Unsaturation
The degree of unsaturation for hydrocarbons is U = (2C + 2 − H) / 2, where C is the number of carbon atoms and H is the number of hydrogen atoms.