Related Experiment Video
Updated: Feb 9, 2026

Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Low temperature increases capillary blood refill time following mechanical fingertip compression of healthy
Koichiro Shinozaki1, Michael J Capilupi2, Kota Saeki3
1The Feinstein Institute for Medical Research, Northwell Health System, 350 Community Dr., Manhasset, NY, 11030, USA. shino@gk9.so-net.ne.jp.
Abstract:
Capillary refill time has been accepted as a method to manually assess a patient's peripheral blood perfusion. Recently, temperature has been reported to affect capillary refill time and therefore temperature may interfere with accurate bedside peripheral blood perfusion evaluation. We applied a new method of analysis that uses standard hospital pulse oximetry equipment and measured blood refill time in order to test whether lowered fingertip temperature alters peripheral blood perfusion. Thirty adult healthy volunteers of differing races (skin colors) and age (young: 18-49 years and old: ≥ 50 years) groups were recruited. We created a high fidelity mechanical device to compress and release the fingertip and measure changes in blood volume using infrared light (940 nm). Capillary refill times were measured at the fingertip at three different temperature settings: ROOM TEMPERATURE, COLD by 15 °C cold water, and REWARM by 38 °C warm water. The COLD group has decreased fingertip temperature (23.6 ± 3.6 °C) and increased blood refill time (4.67 s [95% CI 3.57-5.76], p < 0.001). This was significantly longer than ROOM TEMPERATURE (1.96 [1.60-2.33]) and REWARM (1.96 [1.73-2.19]). Blood refill time in older subjects tended to be longer than in younger subjects (2.28 [1.61-2.94] vs. 1.65 [1.36-1.95], p = 0.077). There was a negative correlation (r = - 0.471, p = 0.009) between age and temperature. A generalized linear mixed-effects model revealed that lower temperature (OR 0.63 [95% CI 0.61-0.65], p < 0.001) rather than age (OR 1.00 [0.99-1.01], p = 0.395) was the independent factor most associated with increased blood refill time. Lowered fingertip temperatures significantly increase blood refill time which then returns to baseline when the fingertip is rewarmed. In our limited number of population, we did not find an association with age after the adjustment for the fingertip temperature.
More Related Videos
08:43Isolation of Endothelial Progenitor Cells from Healthy Volunteers and Their Migratory Potential Influenced by Serum Samples After Cardiac Surgery
Published on: February 14, 2017
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Increased Body Temperature
Bioavailability Study Design: Healthy Subjects Versus Patients
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Increasing Function
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Capillary Beds