Related Experiment Video
Updated: Feb 9, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Heart Rate Variability, Clinical and Laboratory Measures to Predict Future Deterioration in Patients Presenting With
Douglas P Barnaby1, Shannon M Fernando2,3, Christophe L Herry4
1Department of Emergency Medicine, Albert Einstein College of Medicine, Bronx, New York.
Background:
Risk stratification of patients presenting to the emergency department (ED) with sepsis can be challenging. We derived and evaluated performance of a predictive model containing clinical, laboratory, and heart rate variability (HRV) measures to quantify risk of deterioration in this population.
Methods:
ED patients aged 21 and older satisfying the 1992 consensus conference criteria for sepsis and able to consent (directly or through a surrogate) were enrolled (n = 1,247). Patients had clinical, laboratory, and HRV data recorded within 1 h of ED presentation, and were followed to identify deterioration within 72 h.
Results:
Eight hundred thirty-two patients had complete data, of whom 68 (8%) reached at least one endpoint. Optimal predictive performance was derived from a combination of laboratory values and HRV metrics with an area under the receiver-operating curve (AUROC) of 0.80 (95% CI, 0.65-0.92). This combination of variables was superior to clinical (AUROC = 0.69, 95% CI, 0.54-0.83), laboratory (AUROC = 0.77, 95% CI, 0.63-0.90), and HRV measures (AUROC = 0.76, 95% CI, 0.61-0.90) alone. The HRV+LAB model identified a high-risk cohort of patients (14% of all patients) with a 4.3-fold (95% CI, 3.2-5.4) increased risk of deterioration (incidence of deterioration: 35%), as well as a low-risk group (61% of all patients) with 0.2-fold (95% CI 0.1-0.4) risk of deterioration (incidence of deterioration: 2%).
Conclusions:
A model that combines HRV and laboratory values may help ED physicians evaluate risk of deterioration in patients with sepsis and merits validation and further evaluation.
More Related Videos
Related Concept Videos
Measuring Reaction Rates
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Heart Failure III: Clinical Manifestations
Mortar Joint Deterioration in Masonry
The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...

