Related Experiment Video
Updated: Feb 9, 2026

Minimum Burning Pressures of Water-based Emulsion Explosives
Published on: October 31, 2017
Pressure guided surgery of compartment syndrome of the limbs in burn patients
D Boccara1, R Lavocat1, S Soussi1
1Paris Diderot University, Plastic, Reconstructive and Cosmetic Surgery Department, Burn Centre, Paris, France.
Abstract:
Compartment syndrome is a serious complication of high voltage electrical burns, limb carbonization and deep circular burns with delayed escharotomy. Without treatment, ischemic tissue damage leads to irreversible necrosis. Treatment is emergency surgical decompression. The burned patient is usually not searchable and cannot always be readily examined because of bulky dressings; diagnosis of compartment syndrome is always hard to make. The pressure transducer used in central arterial catheters is easy available. We used it to measure pressure in muscular compartments. We measured compartment pressure three times at different depths in all cases of electrical burn, carbonization and deep circumferential burns with delayed escharotomy. We also took the pressure in the uninjured limb. The pressure assessment device was composed of a blood pressure transducer commonly used in arterial catheters for arterial pressure monitoring with three connecting branches. The first branch was connected to the 'arterial pressure exit' in the monitoring device. The second, an IV tube, was connected to one litre of physiological serum in a pressure bag inflated to 200 mmHg. The third, also an IV tube with a sterile extension cable, was directly connected to an 18G standard straight needle to be inserted in the tissues for which interstitial pressure had to be measured. In patients with thermal burns, we measured pressure before and after escharotomy. Threshold intracompartmental pressure was 35 mmHg. We carried out pressure assessment of all muscular compartments during and at the end of surgery. The pressure transducer provides a pressure value in all muscular compartments with a time of installation and measuring of less than 5 minutes. Sensitivity is measured at +/- 1 mmHg. Operation is simple, non-operator dependent, and accessible to medical and paramedic teams. The pressure transducer allows accurate diagnosis of early or established compartment syndrome. It requires no additional equipment and its application does not delay therapeutic management. Its use helps with fasciotomy decision, especially after escharotomy, guides the surgeon in the exploration of different compartments and verifies the effectiveness of surgery.
Related Concept Videos
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...
Compartment Models: Two-Compartment Model
Compartment Models: Single-Compartment Model
Three-Compartment Open Model
Arteries of Lower Limbs
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the...

