Related Experiment Video
Updated: Feb 9, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Simplifying the assessment of coronary artery stenosis by enhancing instantaneous wave free ratio
Vincent Spagnoli1, Fabien Picard1, Victor-Xavier Tadros1
1Department of Cardiology, Montréal Heart Institute, Université de Montréal, Montréal, Canada.
Background:
Instantaneous wave free ratio (iFR) does not require adenosine, but has a relatively wide intermediate range where functional assessment remains inconclusive. In this pilot study, we sought to enhance iFR through with the use of intracoronary (IC) saline (iFRs) and contrast media (iFRc) and determine whether these techniques correlated well with fractional flow reserve (FFR).
Methods:
Patients with coronary artery stenosis (CAS) associated with an iFR in the intermediate zone (≥0.86 and ≤0.93) were prospectively assessed with resting distal coronary pressure/aorta pressure (Pd/Pa), iFR, iFRs, iFRc and FFR.
Results:
A total of 40 coronary lesions were studied (40 patients). Pearson correlation coefficients for FFR and iFR, FFR and iFRs, FFR and iFRc were respectively: 0.57 (P=0.0002), 0.80 (P<0.0001) and 0.77 (P<0.0001). Receiver-operating characteristic (ROC) curve analysis showed similar area under the curve (AUC) of iFRs and iFR [0.90 (95% CI: 0.76-1) vs. 0.89 (95% CI: 0.79-0.99), P=0.89]. Youden's index established cut-off values of ≤0.90 for iFR (sensitivity =91%, specificity =74%) and ≤0.78 for iFRs (sensitivity =73%, specificity =100%). In contrast, the AUC of iFRc was superior to the AUC of iFR [0.99 (95% CI: 0.98-1), P=0.049]. iFRc showed excellent accuracy and established cut-off values of ≤0.81 in predicting an FFR value of ≤0.80 (sensitivity =100%, specificity =93%).
Conclusions:
When iFR is in the intermediate zone, functional assessment of CAS by iFR is enhanced with the use of contrast media but not saline. This pilot study could be hypothesis generating for further study to enhance iFR specificity and sensibility.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
08:34Left Atrial Stenosis Induced Pulmonary Venous Arterialization and Group 2 Pulmonary Hypertension in Rat
Published on: November 18, 2018
Related Concept Videos
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology
Coronary Artery Disease V: Interprofessional Care
Coronary Artery Disease III: Clinical Manifestations
Coronary Artery Disease IV: Preventive Measures
Instantaneous Velocity - II