Platelet concentrate as an additive to bone allografts: a laboratory study using an uniaxial compression test
David Putzer1, Markus Dobersberger2, Alex Pizzini3
1Department of Orthopaedics - Experimental Orthopaedics, Medical University of Innsbruck, Innrain 36, 6020, Innsbruck, Austria. david.putzer@i-med.ac.at.
Abstract:
Chemical cleaning procedures of allografts are destroying viable bone cells and denaturing osteoconductive and osteoinductive proteins present in the graft. The aim of the study was to investigate the mechanical differences of chemical cleaned allografts by adding blood, clotted blood; platelet concentrate and platelet gel using a uniaxial compression test. The allografts were chemically cleaned, dried and standardized according to their grain size distribution. Uniaxial compression test was carried out for the four groups before and after compacting the allografts. No statistically significant difference was found between native allografts, allografts mixed with blood, clotted blood, platelet concentrate and platelet concentrate gel regarding their yield limit after compaction. The authors recommend to chemical clean allografts for large defects, optimize their grain size distribution and add platelet concentrate or platelet rich plasma for enhancing as well primary stability as well bone ingrowth.
More Related Videos
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
05:49Procoagulant Platelet Characterization by Measuring Phosphatidylserine Exposure and Microvesicle Release from Human Purified Platelets
Published on: November 29, 2024
Related Concept Videos
Conjugate Addition (1,4-Addition) vs Direct Addition (1,2-Addition)
Conjugate addition results in a thermodynamically stable product. The reaction retains the stronger C=O bond at the expense of the weaker C=C π bond. The process is slow as the β carbon is less electrophilic than the carbonyl carbon.
Direct addition products are...
Serum Laboratory Studies, Stool Test, Breath Test
Conjugate Addition of Enolates: Michael Addition
Additional Subnuclear Structures
The nucleus contains many membrane-less subnuclear organelles or nuclear bodies, such as nucleoli, Cajal bodies, speckles,...
Concentration Cells
Consider the following voltaic cell:
Expressing Solution Concentration
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.