Related Experiment Video
Updated: Feb 9, 2026

Determining the Mechanical Strength of Ultra-Fine-Grained Metals
Published on: November 22, 2021
Microshear Bond Strength of High-viscosity Glass-ionomer to Normal and Caries-affected Dentin Under Simulated
Objectives::
The use of high-viscosity glass-ionomer cements (HVGICs) for atraumatic restorative treatment (ART) restorations is widely practiced with the advent of various HVGICs. However, the bonding of the latter to caries-affected dentin (CAD) should be validated, especially because it is the common substrate left after conservative caries removal following the ART approach. Hence, this study was carried out to evaluate the microshear bond strength (μSBS) of three HVGICs to normal dentin (ND) and CAD under intrapulpal pressure (IPP) simulation.
Methods And Materials::
The occlusal enamel of 90 molars with mid-coronal caries was cut to expose flat dentin surfaces containing both ND and CAD. Dentin substrates (ND and CAD) were differentiated using visual, tactile, caries-detecting dye, and dye-permeability methods. Prepared crown segments were equally divided (n=30) according to the tested HVGICs into GC Fuji IX GP Fast, Fuji IX GP containing chlorhexidine, and zinc-reinforced ChemFil Rock HVGIC. Microcylinders of tested HVGICs were built up on both dentin substrates (n=30 for each tested HVGIC per each substrate) using starch tubes while the specimens were subjected to simulated IPP of 15 mm Hg. The μSBS test was conducted using a universal testing machine, and failure modes were determined using a scanning electron microscope. Data were statistically analyzed using two-way analysis of variance (ANOVA) with repeated measures, one-way ANOVA, and Bonferroni post hoc tests (α=0.05).
Results::
For both dentin substrates (ND and CAD), the μSBS values of ChemFil Rock were significantly higher than those recorded for the other HVGICs. The μSBS values of each tested HVGIC to ND and CAD were not statistically different. Failure modes were mainly mixed.
Conclusions::
Zinc-reinforced HVGIC ChemFil Rock showed superior bonding to ND and CAD compared to the GC Fuji IX GP Fast and Fuji IX with chlorhexidine. However, each of the tested HVGICs showed comparable bonding to both dentin substrates (ND and CAD).
Related Concept Videos
Bonding and Strength of Aggregate
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Ionic Bonds
When atoms gain or lose electrons to achieve a more stable electron configuration they form ions. Ionic bonds are electrostatic attractions between ions with opposite charges. Ionic compounds are rigid and brittle when solid and may dissociate into their constituent ions in water. Covalent compounds, by contrast, remain intact unless a chemical reaction breaks them.
Opposing Charges Hold Ions Together in Ionic Compounds
Ionic bonds are reversible electrostatic interactions between ions...
Viscosity
The SI unit of viscosity is...
Bond Energies and Bond Lengths
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...