Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

5.8K
Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.8K
Finding Electric Potential From Electric Field01:13

Finding Electric Potential From Electric Field

5.7K
For a system of charges, it is easy to calculate the system's potential because potential is a scalar quantity. However, in some instances where calculating the electric field is more straightforward than finding the potential, the electric field is used to calculate the system's potential. For a positive charge, the electric field is radially outward, and the potential is positive at any finite distance from the positive charge. In such an electric field, the motion away from the...
5.7K
Determining Electric Field From Electric Potential01:12

Determining Electric Field From Electric Potential

5.0K
The electric field and electric potential are related to each other. If the electric field at various points in the region of interest is known, it can be used to calculate the electric potential difference between any two points. Similarly, if the electric potential is known for various points, then it is possible to calculate the electric field.
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
5.0K
Calculations of Electric Potential I01:15

Calculations of Electric Potential I

2.6K
Consider a ring of radius R with a uniform charge density λ. What will the electric potential be at point M, which is located on the axis of the ring at a distance x from the center of the ring?
The ring is divided into infinitesimal small arcs such that point M is equidistant from all the arcs. Here, the cylindrical coordinate system is used to calculate the electric potential at point M. A general element of the arc between angles θ and θ + dθ is of the length Rdθ and has a charge of...
2.6K
Calculations of Electric Potential II01:27

Calculations of Electric Potential II

2.3K
An electric dipole is a system of two equal but opposite charges, separated by a fixed distance. This system is used to model many real-world systems, including atomic and molecular interactions. One of these systems is the water molecule, but only under certain circumstances. These circumstances are met inside a microwave oven, where electric fields with alternating directions make the water molecules change orientation. This vibration is equivalent to heat at the molecular level.
Consider a...
2.3K
Electric Potential Energy01:20

Electric Potential Energy

7.5K
When an electric field accelerates a free positive charge q, it is given kinetic energy. The process is analogous to an object accelerated by a gravitational field as if the charge were going down an electrical hill where its electric potential energy is converted into kinetic energy. Of course, the sources of the forces are very different. The work done on a charge q by the electric field in this process helps to develop a definition of electric potential energy.
The electrostatic or Coulomb...
7.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Entropy for Prediction of MACEs in Myocarditis: A Cardiac MRI-based Biomarker of Myocardial Tissue Heterogeneity.

Radiology·2026
Same author

Fully automated free-breathing cardiac magnetic resonance imaging at 3T: A prospective randomized study of image quality, efficiency, and workflow burden.

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance·2026
Same author

Impact of formalin fixation on biventricular parameters in cardiac diffusion tensor imaging: A pilot study in a miniature swine model.

The international journal of cardiovascular imaging·2026
Same author

Effects of dietary chitosan oligosaccharide on juvenile grass carp: Insight from the intestinal microbiota and metabolism.

Journal of fish biology·2026
Same author

A robust immobilized system using Rhodococcus pyridinivorans YY802 for the efficient dissipation of refractory monomethylanilines in wastewater.

Journal of hazardous materials·2026
Same author

Toxic Effects of Dietary and Waterborne PCB-153 on Survival, Growth, Grazing, and Physiological Responses in Artemia salina Using an Intermittent Exposure Approach.

Journal of applied toxicology : JAT·2026

Related Experiment Video

Updated: Feb 9, 2026

Engineering Skeletal Muscle Tissues from Murine Myoblast Progenitor Cells and Application of Electrical Stimulation
08:38

Engineering Skeletal Muscle Tissues from Murine Myoblast Progenitor Cells and Application of Electrical Stimulation

Published on: March 19, 2013

21.6K

Exploring the Potential of Electrical Impedance Tomography for Tissue Engineering Applications.

Hancong Wu1, Wenli Zhou2, Yunjie Yang3

  • 1Agile Tomography Group, School of Engineering, The University of Edinburgh, Edinburgh EH9 3JL, UK;hason.wu@ed.ac.uk (H.W.). hason.wu@ed.ac.uk.

Materials (Basel, Switzerland)
|June 3, 2018
PubMed
Summary

Electrical impedance tomography (EIT) offers a non-destructive method for monitoring cell growth in tissue engineering. This technology can assess cell viability within biomaterials, overcoming limitations of traditional destructive assays.

Keywords:
cell viabilityelectrical impedance tomographyhydrogelsscaffoldstissue engineering

More Related Videos

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
05:56

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

Published on: September 6, 2024

6.3K
Experimental Approaches to Tissue Engineering
16:41

Experimental Approaches to Tissue Engineering

Published on: August 30, 2007

6.8K

Related Experiment Videos

Last Updated: Feb 9, 2026

Engineering Skeletal Muscle Tissues from Murine Myoblast Progenitor Cells and Application of Electrical Stimulation
08:38

Engineering Skeletal Muscle Tissues from Murine Myoblast Progenitor Cells and Application of Electrical Stimulation

Published on: March 19, 2013

21.6K
Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
05:56

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

Published on: September 6, 2024

6.3K
Experimental Approaches to Tissue Engineering
16:41

Experimental Approaches to Tissue Engineering

Published on: August 30, 2007

6.8K

Area of Science:

  • Biomaterials Science
  • Tissue Engineering
  • Biomedical Engineering

Background:

  • Tissue engineering relies on culturing cells in biomaterials to create artificial tissues for repair and functional restoration.
  • Current methods for assessing cell growth and viability in biomaterials are destructive, limiting real-time monitoring.
  • Detecting subtle conductivity changes from sparse cell distributions in large scaffolds is a significant challenge.

Purpose of the Study:

  • To explore electrical impedance tomography (EIT) as a label-free, non-destructive technology for assessing cell growth and viability in tissue engineering scaffolds.
  • To address the challenge of detecting small conductivity variations caused by low cell volume fractions within biomaterials.
  • To demonstrate the feasibility of using EIT for monitoring cell proliferation and tissue development.

Main Methods:

  • Utilized custom-built electrical impedance tomography (EIT) equipment for measurements.
  • Cultured cells within both hydrogel and microporous biomaterial scaffolds.
  • Implemented a frequency difference technique to enhance the sensitivity and accuracy of conductivity measurements and image reconstruction.

Main Results:

  • Demonstrated proof-of-principle for using EIT to monitor cell growth in biomaterial scaffolds.
  • Successfully measured conductivity changes associated with cell presence in different scaffold types.
  • The frequency difference technique showed improved reconstruction of conductivity changes, even with sparse cell distributions.

Conclusions:

  • Electrical impedance tomography (EIT) is a promising non-destructive technique for monitoring cell growth and viability in tissue engineering.
  • The developed EIT approach, particularly with the frequency difference method, can detect subtle conductivity changes crucial for assessing early-stage tissue development.
  • EIT offers a label-free alternative to destructive assays, enabling real-time monitoring of cell-biomaterial interactions.