Intra- and interobserver variability in the diagnosis of GERD by real-time MRI
Ali Seif Amir Hosseini1, Alexander Beham2, Johannes Uhlig1
1Department of Diagnostic and Interventional Radiology, University Medical Center, Göttingen, Germany.
Abstract:
The purpose of this study was to assess the reproducibility of functional and anatomical parameters of swallowing events as determined by real-time MRI at 40 ms temporal resolution (25 frames per second). Twenty-three consecutive patients with gastroesophageal reflux disease (GERD) underwent real-time MRI of the gastroesophageal junction at 3.0 T. Real-time MRI was based on highly undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion (NLINV). MRI movies visualized the esophageal transport of a pineapple juice bolus, its passage through the gastroesophageal junction and functional responses during a Valsalva maneuver. His-angle, sphincter position, sphincter length and sphincter transit time were assessed by two radiologists. Interobserver and intraobserver intraclass correlation coefficients (ICC) were evaluated and Bland-Altman plots were constructed to assess the observer agreement. Interobserver agreement was excellent for sphincter transit time (ICC = 0.92), His-angle (ICC = 0.93), His-angle during Valsalva maneuver (ICC = 0.91) and sphincter-to-diaphragm distance (ICC = 0.98). Sphincter length and oesophageal diameter showed good interobserver agreement (ICC = 0.62 and ICC = 0.70). Intraobserver agreement was good for sphincter length (ICC = 0.80) and excellent for sphincter transit time, His-angle and His-angle during Valsalva maneuver, sphincter-to-diaphragm distance, and esophageal diameter (ICC = 0.91; ICC = 0.97; ICC = 0.97; ICC = 0.998; ICC = 0.93). All functional parameters of the gastroesophageal junction had good to excellent reproducibility. Visual assessment of Bland Altman plots did not reveal any systematic interobserver bias. In conclusion, the visualization of swallowing events by real-time MRI has a high potential for clinical application in gastroesophageal reflux disease.
Related Concept Videos
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Graphs of Equations in Two Variables
Variables Affecting Phosphorescence and Fluorescence
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...