Related Experiment Video
Updated: Feb 9, 2026

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Investigating the limits of resin-based luting composite photopolymerization through various thicknesses of indirect
C M F Hardy1, S Bebelman2, G Leloup3
1School of Dental Medicine and Stomatology, at Cliniques Universitaires Saint-Luc, Universite catholique de Louvain, Belgium; Advanced Drug Delivery and Biomaterials (ADDB), Louvain Drug Research Institute (LDRI), Université catholique de Louvain, Brussels, Belgium; Bio- and Soft- Matter (BSMA), Institute of Condensed Matter and Nanoscience (IMCN), Université catholique de Louvain, Louvain-la-Neuve, Belgium.
Objective:
To determine the limitations of using light-curable resin-based luting composites (RBLCs) to bond indirect ceramic/resin-composite restorations by measuring light transmittance through indirect restorative materials and the resulting degree of conversion (DC) of the luting-composites placed underneath.
Methods:
Various thicknesses (0-4mm) and shades of LAVA Zirconia and LAVA Ultimate were prepared and used as light curing filters. A commercial, light curable RBLC, RelyX Veneer (control) was compared with four experimental RBLCs of the following composition: TEGDMA/BisGMA (50/50 or 30/70wt%, respectively); camphorquinone/amine (0.2/0.8wt%) or Lucirin-TPO (0.42wt%); microfillers (55wt%) and nanofillers (10wt%). RBLCs covered with the LAVA filter were light-cured for 40s, either with the dual-peak BluephaseG2 or an experimental device emitting either in the blue or violet visible band. The samples were analyzed by Raman spectroscopy to determine DC. Light transmittance through the filters was measured using a common spectroscopy technique.
Results:
All the factors studied significantly influenced DC (p<0.05). RBLCs with increased TEGDMA content exhibited higher DC. Only small differences were observed comparing DC without filters and filters ≤1mm (p>0.05). For thicknesses ≥2mm, significant reductions in DC were observed (p<0.05). Transmittance values revealed higher filter absorption at 400nm than 470nm. A minimal threshold of irradiance measured through the filters that maintained optimal DC following 40s irradiation was identified for each RBLC formulation, and ranged between 250-500mW/cm2.
Significance:
This work confirmed that optimal photopolymerization of RBLCs through indirect restorative materials (≤4mm) and irradiation time of 40s is possible, but only in some specific conditions. The determination of such conditions is likely to be key to clinical success, and all the factors need to be optimized accordingly.
Related Concept Videos
Restorative Care
Solution Composition During Acid/Base Titrations
The α0 and α1 values...
Limiting Reactant
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Indirect Motor Pathways
The vestibulospinal tract originates in the vestibular nuclei of the brainstem. The vestibular system detects changes in...
The Number e as a Limit

