First clinical use of novel ablation catheter incorporating local impedance data
Claire A Martin1,2,3, Ruairidh Martin1,4, Parag R Gajendragadkar2
1LIRYC/Hopital du Haut Leveque, Bordeaux, France.
Introduction:
Successful catheter ablation is limited by both poor spatial resolution of abnormal local signals and inability to deliver an effective lesion due to poor tissue contact. We report first worldwide use of the Intellanav MiFi OI catheter (Boston Scientific), providing ultra-high density mapping and incorporating a "DirectSense" algorithm to measure local tissue impedance (LI).
Methods And Results:
31 patients (65±6 years, 20 male) underwent ablation. LI from the catheter, generator impedance (GI) and maximum electrogram amplitude were recorded in the blood pool, and in regions from healthy to dense scar before, during and after ablation. The catheter demonstrated clear nearfield signal where standard bipolar recordings included farfield signal. LI was lower in dense scar than either healthy tissue or blood pool, and demonstrated an exponential relationship with maximum electrogram amplitude. Maximum LI drop on ablation linearly correlated with initial LI. The median LI drop for successful lesions, resulting in lack of local tissue capture, was 16.0Ω (12.1-19.8 Ω) for LV and 14.6 Ω (10.0-18.3 Ω) for LA, which was larger than for unsuccessful lesions (LV: 9.4 Ω [5.4-15.6 Ω] P = 0.001; LA: 6.8 Ω [4.7-13.0 Ω], P = 0.049). LI percentage drop was also significantly larger for successful than unsuccessful lesions (LV: 17.1 Ω [14.0-19.6 Ω] vs. 10.6 Ω (7.1-16.5 Ω) P = 0.002; LA: 14.2 Ω [10.8-19.5 Ω] vs. 7.5Ω [5.1-11.0 Ω], P = 0.005).
Conclusion:
This novel catheter gives reproducible recordings of local impedance, which are dependent on scar level. Absolute LI drop, and also percentage drop, on ablation may give an indication of tissue contact and subsequent effective lesion formation.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
Related Concept Videos
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Statistical Software for Data Analysis and Clinical Trials
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...