Related Experiment Video
Updated: Feb 9, 2026

A Bedside, Single Burr Hole Approach to Multimodality Monitoring in Severe Brain Injury
Published on: March 26, 2019
Adjustable and Rigid Fixation of Brain Tissue Oxygenation Probe (Licox) in Neurosurgery: From Bench to Bedside
Daniel Pinggera1, Ondra Petr1, Gabriel Putzer2
1Department of Neurosurgery, Medical University Innsbruck, Innsbruck, Austria.
Abstract:
Multimodal neuromonitoring has become a fundamental part of management for many neurosurgical disorders such as subarachnoid hemorrhage and severe traumatic brain injury. Brain tissue oxygen tension monitoring requires insertion of a probe into the brain parenchyma through a single multiple lumen bolt, or in a subcutaneously tunneled fashion. As those patients often require early magnetic resonance imaging, typically using bolts is disadvantageous due to massive metal artifact. Similarly, subcutaneous tunneling is often problematic as suture fixation can loosen over time. We hereby report a new method of fixation of the Licox brain tissue oxygenation probe with 1 or 2 3-way taps that are attached to a standard plastic cannula, resulting in a stable connection with no need for further direct sutures around the probe and above all with no metal artifacts, which negates magnetic resonance imaging. The extended fixation system was first tested with cardiopulmonary resuscitation in a brain injured porcine model. It was thereafter adopted in our daily clinical practice.
Related Concept Videos
The Anchoring-and-Adjustment Heuristic
Adjusting a Traverse
Rigid Body Equilibrium Problems - I
Rigid Body Equilibrium Problems - II
Consider two children sitting on a seesaw, which has negligible mass. The first child has a mass (m1) of 26 kg and sits at point A, which is 1.6 meters (r1) from the pivot point B; the second child has a mass (m2) of 32 kg and sits at point C. How far from the pivot point B should the second child sit (r2) to balance the seesaw?
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...

