Related Experiment Video
Updated: Feb 9, 2026

Author Spotlight: The Box-Cavity Cortical Approach for Enhanced Evaluation of Biomaterials and Bone Regeneration
Published on: November 21, 2023
Marginal quality of ceramic inlays after three different instrumental cavity preparation methods of the proximal
Ella A Naumova1, Fabian Schiml2, Wolfgang H Arnold3
1Department of Biological and Material Sciences in Dentistry, School of Dentistry, Faculty of Health, Witten/Herdecke University, Alfred-Herrhausen-Strasse 44, 58455, Witten, Germany. ella.naumova@uni-wh.de.
Objectives:
The marginal quality of ceramic inlays was evaluated after the use of three different instrumental finishing methods in mesio-occluso-distal (mod) cavity boxes in vitro after hydrothermal loading (HTL).
Materials And Methods:
Caries-free human molars were divided into three groups. Mod-cavities were conventionally prepared. Box finishing was performed in every group with rotating (RI), sonic (SI), or ultrasonic (USI) instruments. Surface roughness was examined. Twelve mod-cavities remained untreated. Continuous margin quality was evaluated with scanning electron microscopy (SEM). Ceramic inlays were cemented into cavities. After HTL microleakage, marginal and absolute marginal gaps were examined. All data were analyzed statistically.
Results:
Significant differences were found, between cavity surface roughness of RI and SI groups, the RI and USI groups, but not between microleakage, marginal, absolute marginal gaps after HTL and in proximal marginal quality. No correlations between microleakage and marginal gaps nor between microleakage and surface roughness were found.
Conclusion:
Mod-cavity proximal box finishing with SI or USI resulted in a higher surface roughness than the use of RI. The type of the finishing method did not influence the marginal quality of ceramic inlays. For the mod-cavity finishing, the use of SI and USI could be an alternative instrumental method to conventional RI methods with a lower risk of iatrogenic damage of the adjacent teeth.
Clinical Relevance:
This study allows the practitioner to better determine the proper indications and limitations of the sonic and ultrasonic instruments for mod-cavity proximal box finishing.
Related Concept Videos
Oral Cavity
Teeth: The teeth are the hardest structures in our bodies. Humans have two sets of teeth throughout their lifetime: deciduous (baby) teeth and permanent teeth. Each tooth consists of several parts: the crown (visible part), the root (embedded in the jaw), enamel (hard outer...
Margin of Error
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Instrument Transformers
Uncertainty in Measurement: Reading Instruments