Related Experiment Video
Updated: Feb 9, 2026

A Reversible Silicon Oil-Induced Ocular Hypertension Model in Mice
Published on: November 15, 2019
Comparative assessment of intraocular inflammation following standard or heavy silicone oil tamponade: a prospective
Francesco Semeraro1, Andrea Russo1, Francesco Morescalchi1
1Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.
Purpose:
To evaluate the inflammation associated with the use of standard silicone oil (polydimethylsiloxane; PDMS) and heavy silicone oil (HSO) Densiron-68™ in patients undergoing vitrectomy for retinal detachment.
Materials And Methods:
A prospective study was performed involving 35 patients scheduled to undergo vitrectomy for retinal detachment. Patients received PDMS or Densiron-68™ HSO according to superior or inferior retinal localization of the tears, respectively. For assessing the inflammation, prostaglandin E2 (PGE2 ) and interleukin-1α (IL-1α) levels were evaluated in the aqueous.
Results:
Thirty-five eyes of 35 patients completed the study: 20 eyes received HSO, and 15 eyes received PDMS. The mean aqueous PGE2 level was significantly higher in HSO patients than in PDMS patients (869.16 ± 242.83 pg/ml versus 369.38 ± 209.7 pg/ml, respectively; p < 0.0001). The mean aqueous IL-1α level was also significantly higher in HSO patients than in PDMS patients (81.40 ± 36.9 pg/ml versus 40.8 ± 32.5 pg/ml, respectively; p = 0.002). In HSO, a moderate positive correlation between the endotamponade duration and both PGE2 (r = 0.44; p = 0.05) and IL-1α (r = 0.48; p = 0.033) levels was observed. In PDMS, a strong positive correlation between the endotamponade duration and both PGE2 (r = 0.89; p < 0.0001) and IL-1α (r = 0.68; p = 0.006) levels was observed.
Conclusion:
Although both HSO and PDMS yielded favourable success rates in the surgical treatment of complicated retinal detachments, HSO triggered a more severe inflammatory reaction, in a time-dependent manner.