Differentiation of malignant liver tumors by software-based perfusion quantification with dynamic contrast-enhanced
Dane Wildner1, Barbara Schellhaas1, Daniel Strack1
1Department of Internal Medicine 1, University Hospital Erlangen, Friedrich-Alexander-UniversityErlangen-Nuremberg, Erlangen, Germany.
Abstract:
BACKGROUNDEnhancement patterns on contrast-enhanced ultrasound (CEUS) help to distinguish different liver tumors.
Objective:
Assessing the diagnostic value of dynamic contrast-enhanced ultrasound (DCEUS) for the discrimination of different malignant liver lesions.
Methods:
148 malignant focal liver lesions were assessed prospectively with DCEUS (hepatocellular carcinoma = HCC; cholangiocellular carcinoma = CCC; pancreatic adenocarcinoma = PCA; breast cancer = BC; colorectal cancer = CRC; melanoma = MM). Focal-nodular-hyperplasias (FNH) served as a reference for benign lesions. DCEUS-clips were recorded continuously over three minutes. DCEUS-values were compared between the tumor entities. For better inter-individual comparability, perfusion kinetics were analyzed considering the perfusion characteristics of the surrounding liver parenchyma (Relative Signal Intensity = RSI: lesion-liver tissue/liver tissue) at different points in time.
Results:
Absolute signal intensity in FNH showed a tendency towards higher values compared with malignant liver lesions [Peak Enhancement(a.u.): FNH 7111.4; HCC 549.9; CCC -6654.3; PCA -7307.9; BC -4562.4; CRC -10672.9; MM -3034.1]. Washout was significantly less in FNH versus PCA and CRC, and more pronounced and earlier in PCA and CRC versus HCC [RSI 30 seconds after PE-lesion(%): FNH +52; PCA -65; CRC -76; HCC -26]. Rise Time, Fall Time and mean-Transit-Time did not differ significantly.
Conclusions:
DCEUS-values reflect significant differences between malignant liver lesions, especially at peak enhancement and during the washout phases.
More Related Videos
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation SHAPE Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
Published on: December 5, 2020
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Self-Evaluation: Self-Enhancement and Self-Verification
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Dynamic Equilibrium
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement