The spin-forbidden a 4Σ--X 2Π1/2 transition of GeH detected in absorption using intracavity laser spectroscopy

Jack C Harms1, Leah C O'Brien2, James J O'Brien1

  • 1Department of Chemistry and Biochemistry and Center for Nanoscience, University of Missouri-St. Louis, Saint Louis, Missouri 63121, USA.

Related Concept Videos

NMR Spectroscopy: Spin–Spin Coupling01:08

NMR Spectroscopy: Spin–Spin Coupling

The spin state of an NMR-active nucleus can have a slight effect on its immediate electronic environment. This effect propagates through the intervening bonds and affects the electronic environments of NMR-active nuclei up to three bonds away; occasionally, even farther. This phenomenon is called spin–spin coupling or J-coupling. Coupling interactions are mutual and result in small changes in the absorption frequencies of both nuclei involved. While nuclei of the same element are involved...
3.3K
SN2 Reaction: Transition State02:26

SN2 Reaction: Transition State

An SN2 reaction of an alkyl halide is a single-step process in which bond formation between the nucleophile and the substrate and bond breaking between the substrate and the halide occurs simultaneously through a transition state without forming an intermediate.
When the nucleophile approaches the electrophilic carbon with its lone pairs, the halide acts as a leaving group and moves away with the electron-pair bonded to the carbon. Dotted partial bonds represent the bonds being formed or broken...
12.0K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.1K
Molecular Spectroscopy: Absorption and Emission01:14

Molecular Spectroscopy: Absorption and Emission

Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels.  Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
4.6K
Atomic Absorption Spectroscopy: Overview01:27

Atomic Absorption Spectroscopy: Overview

Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
3.6K
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
1.7K