Related Experiment Video
Updated: Feb 9, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
A multi-institutional study of secondary check of treatment planning using Clarkson-based dose calculation for
Ryo Takahashi1, Tatsuya Kamima1, Masanobu Itano2
1Department of Radiation Oncology, The Cancer Institute Hospital of the Japanese Foundation for Cancer Research, Tokyo 135-8550, Japan.
Purpose:
As there have been few reports on quantitative analysis of inter-institutional results for independent monitor unit (MU) verification, we performed a multi-institutional study of verification to show the feasibility of applying the 3-5% action levels used in the U.S. and Europe, and also to show the results of inter-institutional comparisons.
Methods:
A total of 5936 fields were collected from 12 institutions. We used commercial software employing the Clarkson algorithm for verification after a validation study of measurement and software comparisons was performed. The doses generated by the treatment planning systems (TPSs) were retrospectively analyzed using the verification software.
Results:
Mean ± two standard deviations of all locations were 1.0 ± 3.6%. There were larger differences for breast (4.0 ± 4.0%) and for lung (2.5 ± 5.8%). A total of 80% of the fields with differences over 5% of the action level involved breast and lung targets, with 7.2 ± 5.4%. Inter-institutional comparisons showed various systematic differences for field shape for breast and differences in the fields were attributable to differences in reference point placement for lung. The large differences for breast and lung are partially attributable to differences in the methods used to correct for heterogeneity.
Conclusions:
The 5% action level may be feasible for verification; however, an understanding of larger differences in breast and lung plans is important in clinical practice. Based on the inter-institutional comparisons, care must be taken when determining an institution-specific action level from plans with different field shape settings and incorrectly placed reference points.
Related Concept Videos
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Bioavailability Study Design: Single Versus Multiple Dose Studies
Calculating pH Changes in a Buffer Solution
Secondary Active Transport
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant

