High efficiency gamma camera enables ultra-low fixed dose stress/rest myocardial perfusion imaging
Rene Nkoulou1, Tobias Fuchs2, Aju P Pazhenkottil2
1Department of Cardiology, University Hospitals Geneva, Rue Gabrielle Perret Gentil 4, Geneva, Switzerland.
Aims:
We validated a 1-day myocardial perfusion imaging (MPI) protocol using an ultra low-dose(ULD) equal for stress and rest on a cadmium zinc telluride (CZT).
Methods And Results:
Fifty-six patients underwent a 1-day MPI protocol using a standard (SD) 99mTc-tetrofosmin dose at stress (320 MBq) and rest (960 MBq) with 5 min acquisition time each (SD). Within 2 weeks MPI was repeated using ULD 99mTc-tetrofosmin equal for stress and rest (160 MBq) with 15 min acquisition time each (ULD). All scans were performed on a CZT camera (DNM 570c, GE Healthcare). Background subtraction was applied on the rest MPI of the ULD using P-mod software. Presence and extent of perfusion defect were analysed. Pearson's correlation was used to compare ejection fraction (EF), end diastolic volume (EDV), and end systolic volume (ESV) between both protocols. SD revealed ischaemia in 23, scar in 3, and an equivocal finding in 1 patient, while normal findings were documented in 29 patients. ULD resulted in the following findings: ischaemia 23, scar 3, and 30 normal scans. Congruence of SD and ULD was 22/23 for ischaemia, 3/3 for scar, and 29/29 in normal patients; one patient with ischaemia in SD was classified as scar in ULD. Overall agreement of ULD with SD was 98%. The mean extent of defect was comparable between SD and ULD for the stress (10% vs. 11%, respectively, P = NS) and rest studies (5% vs. 7%, respectively, P = NS). An excellent correlation between SD and ULD was found for EF (r = 0.93), EDV (r = 0.95), and ESV (r = 0.97).
Conclusion:
CZT cameras may enable reliable MPI scanning in patients with known or suspected coronary artery disease using protocols with about a factor 4-decrease in radiation dose exposure compared with traditional protocols.
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
The Resting Membrane Potential
Resting Membrane Potential
The Inside of a Neuron is More Negative
The membrane potential of a cell can be measured by inserting a microelectrode into a cell and comparing the charge to a reference electrode in the extracellular fluid. The...
Resting Potential Decay
At rest, the K+ is the main ion that moves across the membrane...
Pressure Variation in a Fluid at Rest
When measuring pressure at two different levels within the fluid, the difference in...
Fixed Action Patterns