Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Interfacility variation in treatment planning parameters in tomotherapy: field width, pitch, and modulation factor
Hidetoshi Shimizu1,2, Koji Sasaki2, Takashi Kubota1
1Department of Radiation Oncology, Aichi Cancer Center Hospital, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, Japan.
This study surveyed Japanese facilities on tomotherapy planning parameters for head and neck and prostate cancer. Findings reveal variations in pitch and modulation factor (MF) usage, highlighting the need for standardized practices.
Area of Science:
- Medical Physics
- Radiation Oncology
- Radiotherapy Technology
Background:
- Tomotherapy planning parameters like field width (FW), pitch, and modulation factor (MF) influence dose distribution and delivery time.
- Variations in these parameters across different treatment facilities are not well-documented.
Purpose of the Study:
- To determine standard values for FW, pitch, and MF in head and neck cancer (HNC) and prostate cancer (PC) treatment planning using tomotherapy in Japan.
- To identify current practices and variations in parameter selection among Japanese radiation therapy facilities.
Main Methods:
- A web-based questionnaire was distributed to 48 Japanese facilities utilizing tomotherapy.
- Data on commonly used planning parameters (FW, pitch, MF) for HNC and PC were collected from 23 responding facilities (48% response rate).
Main Results:
- Field width (FW) was predominantly 2.5 cm; dynamic FW was used with tomoEDGE licenses.
- Pitch adjustments were more frequent for HNC than PC, influenced by FW, dose per fraction, or target offset.
- Median preset modulation factors (MF) were 2.4 for HNC and 2.0 for PC, with significant inter-facility variation observed.
Conclusions:
- Significant variations exist in tomotherapy planning parameters, particularly pitch and MF, between Japanese facilities for HNC and PC.
- These findings provide valuable insights for facilities aiming to optimize tomotherapy treatment planning and potentially establish standardized protocols.
Related Concept Videos
Factors Influencing Drug Absorption: Anatomical Parameters
Factors Influencing Drug Absorption: Physicochemical Parameters
Enhanced drug absorption can be achieved by reducing particle sizes and increasing surface areas, thereby facilitating...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...