Interfacility variation in treatment planning parameters in tomotherapy: field width, pitch, and modulation factor
Related Experiment Video
Updated: Feb 9, 2026

Radiation Planning Assistant - A Streamlined, Fully Automated Radiotherapy Treatment Planning System
Published on: April 11, 2018
Hidetoshi Shimizu1,2, Koji Sasaki2, Takashi Kubota1
1Department of Radiation Oncology, Aichi Cancer Center Hospital, 1-1 Kanokoden, Chikusa-Ku, Nagoya, Aichi, Japan.
Abstract:
Several studies have reported changes in dose distribution and delivery time based on the value of specific planning parameters [field width (FW), pitch, and modulation factor (MF)] in tomotherapy. However, the variation in the parameters between different facilities is unknown. The purpose of this study was to determine standard values of the above parameters for cases of head and neck cancer (HNC) and prostate cancer (PC) in Japan. In this survey, a web-based questionnaire was sent to 48 facilities performing radiation therapy with tomotherapy in March 2016. The deadline for data submission was April 2016. In the questionnaire, the values of the planning parameters usually used were requested and 23 responses were received, representing a response rate of 48% (23/48). The FW selected was 2.5 cm in most facilities, and facilities with a tomoEDGE license used dynamic FW rather than fixed FW. Facilities changed the pitch based on FW, dose per fraction, or target offset more frequently in HNC than in PC. In contrast, >50% of the facilities used the magic number proposed by Kissick et al. Median preset MFs (range, min to max) in HNC and PC were 2.4 (1.8-2.8) and 2.0 (1.8-3.0), respectively, and MF values showed large variations between the facilities. Our results are likely to be useful to several facilities designing treatment plans in tomotherapy.
Related Concept Videos
Factors Influencing Drug Absorption: Anatomical Parameters
Factors Influencing Drug Absorption: Physicochemical Parameters
Enhanced drug absorption can be achieved by reducing particle sizes and increasing surface areas, thereby facilitating...
Factors Influencing Drug Absorption: Pharmaceutical Parameters
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...