Related Experiment Video
Updated: Feb 9, 2026

Separation of Mouse Embryonic Facial Ectoderm and Mesenchyme
Published on: April 12, 2013
Self-adaptive signal separation for non-contact heart rate estimation from facial video in realistic environments
Xuenan Liu1,2, Xuezhi Yang1,2, Jing Jin1
1School of Computer and Information, Hefei University of Technology, Hefei 230009, People's Republic of China.
Objective:
Recent research indicates that facial epidermis color varies with the rhythm of heat beats. It can be captured by consumer-level cameras and, astonishingly, be adopted to estimate heart rate (HR). The HR estimated remains not as precise as required in a practical environment where illumination interference, facial expressions, or motion artifacts are involved, although numerous methods have been proposed in the last few years. A novel algorithm is proposed to make non-contact HR estimation technique more robust.
Approach:
First, the face of the subject is detected and tracked to follow the head movement. The facial region then falls into several blocks, and the chrominance feature of each block is extracted to establish a raw HR sub-signal. Self-adaptive signal separation is performed to separate the noiseless HR sub-signals from raw sub-signals. On that basis, the noiseless sub-signals full of HR information are selected using a weight-based scheme to establish the holistic HR signal, from which the average HR is computed adopting wavelet transform and data filtering.
Main Results:
Forty subjects took part in our experiments, whose facial videos were recorded by a normal webcam with the frame rate of 30 fps under ambient lighting conditions. The average HR estimated by our method correlates strongly with ground truth measurements, as indicated in experimental results measured in a static scenario with the Pearson correlation r = 0.980 and a dynamic scenario with the Pearson correlation r = 0.897. In addition, our method, compared to the newest method, decreases the error rate by 38.63% and increases the Pearson correlation by 15.59%.
Significance:
This work proposes a robust method for non-contact HR measurement in a realistic environment. Results of comparative experiments indicate that our method out-performs state-of-the-art non-contact HR estimation methods in realistic environments.
Related Concept Videos
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Muscles for Facial Expressions