Immune induction of human monocyte plasminogen activator. Characteristics of an assay for cell-mediated immunity

Insights

This study shows that measuring plasminogen activator (PA) induction in monocytes is a reliable way to detect cell-mediated immunity (CMI). This direct PA induction assay is sensitive, convenient, and uses small blood volumes for health and disease analysis.

Area of Science:

  • Immunology
  • Cell Biology

Background:

  • Cell-mediated immunity (CMI) is crucial for immune responses.
  • Assessing CMI often requires sensitive and convenient in vitro methods.
  • Monocyte plasminogen activator (PA) induction is explored as a potential CMI marker.

Purpose of the Study:

  • To determine if assaying monocyte plasminogen activator (PA) induction reliably detects cell-mediated immunity (CMI).
  • To evaluate the sensitivity and convenience of a direct PA induction assay compared to other methods.

Main Methods:

  • Mononuclear leukocytes (MNL) were cultured with mitogens (PHA, Con A) or Candida antigen.
  • Plasminogen activator (PA) activity in monocytes was measured using a micro fibrin plate assay.
  • Compared direct PA induction assay with indirect assays for PA and leukocyte inhibitory factor (LIF).

Main Results:

  • Stimulated monocytes showed significantly higher PA activity than unstimulated monocytes, peaking at 2 days.
  • PA induction occurred at sub-mitogenic concentrations of stimuli and correlated with skin test results.
  • The direct PA induction assay was more sensitive and convenient than indirect assays.

Conclusions:

  • Direct assay of PA induction in monocytes is a sensitive and convenient method for in vitro CMI analysis.
  • This assay may be valuable for assessing cell-mediated immunity in various health and disease states.
  • PA induction serves as a reliable indicator of cell-mediated immune responses.