Related Experiment Video
Updated: Feb 9, 2026

Measuring Hypopharyngeal Gland Acinus Size in Honey Bee Apis mellifera Workers
Published on: September 14, 2018
A Nonlethal Method to Examine Non-Apis Bees for Mark-Capture Research
Natalie K Boyle1, Amber D Tripodi1, Scott A Machtley2
1USDA-ARS Pollinating Insects Research Unit, Utah State University, Logan, UT.
Abstract:
Studies of bee movement and activities across a landscape are important for developing an understanding of their behavior and their ability to withstand environmental stress. Recent research has shown that proteins, such as egg albumin, are effective for mass-marking bees. However, current protein mass-marking techniques require sacrificing individual bees during the data collection process. A nonlethal sampling method for protein mark-capture research is sorely needed, particularly for vulnerable, sensitive, or economically valuable species. This study describes a nonlethal sampling method, in which three non-Apis bee species (Bombus bifarius Cresson [Hymenoptera: Apidae], Osmia lignaria Say [Hymenoptera: Megachilidae], and Megachile rotundata Fabricius [Hymenoptera: Megachilidae]) were tested for a unique protein marker by immersing them momentarily in saline buffer and releasing them. Results showed that an egg albumin-specific enzyme-linked immunosorbent assay was 100% effective at detecting the protein on bees that were sampled nonlethally. Furthermore, this sampling method did not have an impact on bee survivorship, suggesting that immersing bees in buffer is a reliable and valid surrogate to traditional, destructive sampling methods for mark-capture bee studies.
Related Concept Videos
Bone Markings
Articulating Projections
Articulating projections are found where two bones meet to form a joint. These structures are usually found at the ends of bones. The largest articulation is a rounded projection called the head, supported by a narrow neck at the ends of...
Design Example: Marking Boundaries of a Site Using a Compass
Urologic Endoscopic Procedure: Cystoscopic Examination
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
The Scientific Method
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...

