Related Experiment Video
Updated: Feb 9, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
A sensitive and specific solid-phase extraction-gas chromatography-tandem mass spectrometry method for the
Aziz Kinani1,2, Jérôme Olivier1, Adrien Roumiguières1
11 Division Recherche et Développement, Laboratoire National d'Hydraulique et Environnement (LNHE), Electricité de France (EDF), Chatou Cedex, France.
Abstract:
A method for the analysis of 11 haloacetic acids in water samples has been developed. It involves enrichment of the target analytes from water samples by solid-phase extraction, derivatization to methyl esters, and gas chromatography coupled with tandem mass spectrometry determination. Gas chromatography conditions were optimized for a good separation of all haloacetic acids in a short runtime. Data were acquired in the multiple reaction monitoring mode. Six solid-phase extraction sorbents among the most widely used in environmental analysis were tested. Bakerbond SDB was retained because it has been shown to provide the best results for a large class of targeted haloacetic acids. The performances of the developed method have been assessed according to the French Standard NF T 90-210. The calibration curves for all the studied haloacetic acids had consistent slopes with r2 values > 0.99. Quantification limits between 0.01 and 0.50 µg l-1 were achieved. Satisfactory repeatability (relative standard deviation ≤ 14.3%) and intermediate precision (relative standard deviation ≤ 15.7%) were obtained. Applied to the analysis of 15 untreated water samples collected from three rivers, the method allowed the detection of five haloacetic acids including monochloroacetic acid (in 100% of the samples, <0.5-1.85 µg l-1), dichloroacetic acid (87%, <0.05-0.22 µg l-1), trichloroacetic acid (93%, <0.05-0.52 µg l-1), dibromoacetic acid (53%, <0.01-0.40 µg l-1), tribromoacetic acid (20%, <0.05-0.14 µg l-1), and bromodichloroacetic acid (6%, < 0.05 µg l-1).
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...