Related Experiment Video
Updated: Feb 9, 2026

Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
Effects of low-intensity laser therapy on the stability of orthodontic mini-implants: a randomised controlled
Ahmed Mohamed Abohabib1, Mona Mohamed Fayed2,3, Amr H Labib2
1a Faculty of Dentistry , Kafrelsheikh University , Karfelskeikh , Egypt.
Objective:
To investigate the effect of low-intensity laser therapy on mini-implant stability using resonance frequency analysis during canine retraction with fixed appliances.
Design:
A split-mouth randomised clinical trial.
Setting:
Subjects were recruited and treated in the outpatient clinic, Department of Orthodontics, Faculty of Dentistry, Cairo University.
Participants:
Fifteen subjects with mean age 20.9 (±3.4) years who required extraction of maxillary first premolar teeth and mini-implant-supported canine retraction.
Methods:
Thirty orthodontic mini-implants were inserted bilaterally in the maxillary arches of recruited subjects following alignment and levelling. Mini-implants were immediately loaded with a force of 150 g using nickel titanium coil springs with split-mouth randomisation to a low-intensity laser-treated side and control side. The experimental sides were exposed to low-intensity laser therapy from a diode laser with a wavelength of 940 nm at (0, 7, 14, 21 days) after mini-implant placement. Mini-implant stability was measured using resonance frequency analysis at (0, 1, 2, 3, 4, 6, 8, 10 weeks) after implant placement.
Results:
A total sample of 28 mini-implants were investigated with 14 in each group. Clinically, both mini-implant groups had the same overall success rate of 78.5%. There were no significant differences in resonance frequency scores between low-intensity laser and control sides from baseline to week 2. However, from week 3 to 10, the low-intensity laser sides showed significantly increased mean resonance frequency values compared to control (P > 0.05).
Conclusions:
Despite evidence of some significant differences in resonance frequency between mini-implants exposed to low-intensity laser light over a 10 weeks period there were no differences in mini-implant stability. Low-intensity laser light cannot be recommended as a clinically useful adjunct to promoting mini-implant stability during canine retraction.
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Nuclear Stability
To hold positively charged protons together...
Trial and Error and Algorithm
RNA Stability

