Related Experiment Video
Updated: Feb 9, 2026

Establishing Dual Resistance to EGFR-TKI and MET-TKI in Lung Adenocarcinoma Cells In Vitro with a 2-step Dose-escalation Procedure
Published on: August 11, 2017
Incoherent dose-escalation in phase I trials using the escalation with overdose control approach
1MRC Biostatistics Unit Hub for Trials Methodology Research, Cambridge Institute of Public Health, Cambridge CB2 0SR, UK.
None:
A desirable property of any dose-escalation strategy for phase I oncology trials is coherence: if the previous patient experienced a toxicity, a higher dose is not recommended for the next patient; similarly, if the previous patient did not experience a toxicity, a lower dose is not recommended for the next patient. The escalation with overdose control (EWOC) approach is a model-based design that has been applied in practice, under which the dose assigned to the next patient is the one that, given all available data, has a posterior probability of exceeding the maximum tolerated dose equal to a pre-specified value known as the feasibility bound. Several methodological and applied publications have considered the EWOC approach with both feasibility bounds fixed and increasing throughout the trial. Whilst the EWOC approach with fixed feasibility bound has been proven to be coherent, some proposed methods of increasing the feasibility bound regardless of toxicity outcomes of patients can lead to incoherent dose-escalation. This paper formalises a proof that incoherent dose-escalation can occur if the feasibility bound is increased without consideration of preceding toxicity outcomes, and shows via simulation studies that only small increases in the feasibility bound are required for incoherent dose-escalations to occur.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Clinical Trials: Overview
Trial and Error and Algorithm