Dataset on fabrication of an improved L-lactate biosensor based on lactate oxidase/cMWCNT/CuNPs/PANI modified PG
1Department of Biochemistry, Maharshi Dayanand University, Rohtak, India.
Abstract:
The data shown in this article are based on the original research article entitled "An improved amperometric L-lactate biosensor based on covalent immobilization of microbial lactate oxidase onto carboxylated multiwalled carbon nanotubes/copper nanoparticles/ polyaniline modified pencil graphite electrode" (Dagar and Pundir, 2017) [1]. This article explains the fabrication of an amperometric L-lactate biosensor based on microbial lactate oxidase (LOx) covalent immobilization onto nanomatrix [(carboxylated multiwalled carbon nanotubes (cMWCNT)/copper nanoparticles (CuNPs)/polyaniline (PANI) hybrid film/pencil graphite electrode (PGE)]. The dataset based on this article is made publically available for critical analysis. The whole data is supplied in the research article instead of repository. The data in the article is not related to any already published article.
More Related Videos
06:18Mapping Metabolism: Monitoring Lactate Dehydrogenase Activity Directly in Tissue
Published on: June 21, 2018
10:45Simultaneous Electroencephalography, Real-time Measurement of Lactate Concentration and Optogenetic Manipulation of Neuronal Activity in the Rodent Cerebral Cortex
Published on: December 19, 2012
Related Concept Videos
Standard Electrode Potentials
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Improving Translational Accuracy
Improving Translational Accuracy
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...