Related Experiment Video
Updated: Feb 9, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
Influence of observer experience on cardiac magnetic resonance strain measurements using feature tracking and
Andreas Feisst1, Daniel L R Kuetting1, Darius Dabir1
1Department of Radiology, University of Bonn, Sigmund-Freud-Str.25, 53127 Bonn, Germany.
Aim:
CMR quantitative myocardial strain analysis is increasingly being utilized in clinical routine. CMR feature tracking (FT) is now considered an alternative to the reference standard for strain assessment -CMR tagging. The impact of observer experience on the validity of FT results has not yet been investigated. The aim of this study was therefore to evaluate the observer experience-dependency of CMR FT and to compare results with the reference standard.
Methods:
CSPAMM and SSFP-Cine sequences were acquired in 38 individuals (19 patients with HFpEF,19 controls) in identical midventricular short-axis locations. Global peak systolic circumferential strain (PSCS) together with LV ejection fraction (EF) and volumes were assessed by three observers (5,3 and 0 years of CMR-strain experience). Intermodality, intra- as well inter-observer variability were assessed.
Results:
Correlation between tagging and FT derived PSCS depended on observer experience (r = 0.69, r = 0.58 and r = 0.53). For the inexperienced observer tagging and FT derived PSCS differed significantly (p = 0.0061). Intra-observer reproducibility of tagging derived PSCS were similar for all observers (coefficient of variation (CV): 6%, 6.8% and 4.9%) while reproducibility of FT derived PSCS (CV: 7.4%, 9.4% and 15.8%) varied depending on observer experience. Inter-observer reproducibility of tagging derived PSCS for observer 1 and 2 as well as 1 and 3 for tagging (CV: 6.17%, 9.18%) was superior in comparison to FT (CV: 11.8%, 16.4%).
Conclusions:
Reliability and accuracy of FT based strain analysis, more than tagging based strain analysis, is dependent on reader experience. CMR strain experience or dedicated training in strain evaluation is necessary for FT to deliver accurate strain data, comparable to that of CMR tagging.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Measurements of Strain
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Imaging Studies IV: Magnetic Resonance Imaging