Related Experiment Video
Updated: Feb 9, 2026

Immunohistochemistry Test for the Lyssavirus Antigen Detection from Formalin-Fixed Tissues
Published on: October 26, 2021
Early detection of prostate carcinogens by immunohistochemistry of HMGB2
Shugo Suzuki1,2, Hiroyuki Kato1, Satoshi Fuji1
1Department of Experimental Pathology and Tumor Biology, Nagoya City University Graduate School of Medical Sciences.
Abstract:
Screening prostatic carcinogens is time-consuming due to the time needed to induce preneoplastic and neoplastic lesions. To overcome this, we investigated alternative molecular markers for detection of prostatic carcinogens in a short period in rats. After treatment with 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP), expression of high-mobility group protein B2 (HMGB2) was up-regulated in rat ventral prostate. To evaluate the applicability of HMGB2 in the early detection of carcinogenicity of chemicals using animal models, we examined HMGB2 expression in prostate of rats. Six-week-old male F344 rats were gavaged for four weeks with a total of eight individual chemicals, divided into two categories based on prostate carcinogenicity. Animals were sacrificed at the end of the study and HMGB2 immunohistochemistry was performed. HMGB2 expression in least one prostate lobe was significantly increased by all four prostate carcinogens compared with the controls. In contrast, the four chemicals that were not carcinogenic in the prostate did not cause HMGB2 up-regulation. Additionally, high HMGB2 expression in neoplastic lesions in both rat and human was detected. Therefore HMGB2 expression may be a good screening tool for the identification of potential of prostate carcinogens.
Related Concept Videos
Mutagenicity and Carcinogenicity
Immunocytochemistry and Immunohistochemistry
These...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

