Salutary Effects of the PULVAD, a Novel Implantable Counterpulsation Assist Device, on Cardiac Mechanoenergetics
Christos Kontogiannis1, Dionysios Aravantinos1, Ioannis Nanas1
1From the 3rd Department of Cardiology, University of Athens School of Medicine, Athens, Greece.
Abstract:
The Pressure Unloading Left Ventricular Assist Vevice (PULVAD) is a novel implantable counterpulsation LVAD, designed to provide ventricular unloading with augmentation of LV performance and retention of pulsatility. We assessed the effects of the PULVAD on hemodynamics and LV mechanoenergetics in seven farm pigs with acute ischemic heart failure. The PULVAD was implanted in the thorax and was connected to the ascending aorta. The PULVAD was pneumatically driven by a standard intra-aortic balloon pump console and was electrocardiogram-synchronized to provide LV pressure unloading along with diastolic aortic pressure augmentation. Hemodynamics, indices of LV mechanoenergetics, and coronary blood flow were measured without and after brief PULVAD support. PULVAD support decreased LV afterload and improved LV mechanical performance (increased ejection fraction, stroke volume, cardiac output and maximum elastance). The PULVAD concurrently reduced LV energy consumption (decreased stroke work and pressure-volume area) and optimized LV energetic performance (improved the ratio of stroke work to pressure-volume area). PULVAD support increased mean coronary blood flow, through dramatic augmentation of diastolic blood flow. In conclusion, the PULVAD unloads the failing LV, optimizes LV mechanoenergetics, and augments coronary blood flow. These salutary effects of short-term PULVAD support provide the foundation for long-term testing.
Related Concept Videos
Biological Effects of Radiation
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Framing Effects
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...