Related Experiment Video
Updated: Feb 9, 2026

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Rapid paper based colorimetric detection of glucose using a hollow microneedle device
Dean Nicholas1, Keiran A Logan1, Yingjie Sheng1
1Biomedical Sciences Research Institute, University of Ulster, Coleraine, Northern Ireland BT52 1SA, UK.
Abstract:
The monitoring of blood glucose is a key aspect of diabetes care in limiting the negative effects of hyperglycaemia to both the microvasculature and macrovasculature. Self-monitoring of blood glucose (SMBG) gives an indication of blood glucose at a specific point in time and is recommended to be carried out four times daily. However, due to the inconvenience and associated pain of blood withdrawal, SMBG is often carried out less frequently than recommended or not at all. Extraction and subsequent determination of glucose in interstitial fluid (ISF) using microneedles (MNs) is an emerging area of research due to their minimally invasive nature and lack of associated pain. In this manuscript, a novel method for the fabrication of a hollow microneedle device is reported. The microneedle produced had a sharp bevelled edge and was 400 µm in length. Additionally, a paper backplate embedded with a colorimetric system for the rapid visual determination of glucose in simulated ISF was developed and paired with the hollow MN. This device rapidly extracted simulated ISF within five seconds and its ability to produce a glucose concentration dependent colour change within 30 s was demonstrated. Using this approach, it was possible to discriminate between glucose concentrations in normal glycaemia (4-7 mM) and hyperglycaemia (>7 mM) ranges using the naked eye. While further development is required, the results herein highlight the potential of this device to be used as a blood-free minimally invasive approach to glucose monitoring.
More Related Videos
06:00Author Spotlight: Development of a Smartphone-Enhanced Paper-Based Device for Rapid Dengue NS1 Detection
Published on: January 26, 2024
12:50Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014
Related Concept Videos
Thin-Walled Hollow Shafts
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Glucose Transporters
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Glucose Absorption Into the Small Intestine
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...