Related Experiment Video
Updated: Feb 9, 2026

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device
Cosimo Alex Leo1,2, Emanuel Cavazzoni3, Gregory P Thomas1
1London North West NHS Trust - St Mark's Hospital Academic Institute, Sir Alan Park's Physiology Unit, Harrow, UK.
Background/Aims:
The Anopress device is a new portable manometry system. The aim of this study is to formulate normative data using this new device by recording the anorectal function of asymptomatic subjects. Patient comfort was also assessed.
Methods:
Anorectal function was assessed in asymptomatic volunteers using the Anopress. All volunteers were examined in a standardized way in accordance with the study protocol. Normative values for the Anopress were obtained from the recorded data and patient comfort was assessed using a visual analogue scale.
Results:
We recruited 153 healthy volunteers. Eighty were female (23 parous; median age 39.5 [interquartile range {IQR}, 28.75-53.00]) and 73 were male (median age 40.5 [IQR, 29.00-52.25]). For the female cohort, the following normal range (2.5-97.5 percentile) values were recorded across the whole anal canal: resting pressure 40.0-103.0 mmHg; squeeze increment 35.0-140.6 mmHg; endurance 1.3-9.0 seconds; involuntary squeeze 41.1-120.8 mmHg; and strain pressure 22.1-77.9 mmHg. Similarly, the following male normal range (2.5-97.5 percentile) values were recorded across the whole anal canal: resting pressure 38.3-99.6 mmHg; squeeze increment 42.5-154.8 mmHg; involuntary squeeze 40.0-123.6 mmHg; endurance 2.0-10.0 seconds; and strain pressure 11.0-72.1 mmHg. The median visual analogue scale scores for discomfort during the measurement was 0.0 (IQR, 0.00-0.00).
Conclusions:
Normative values for the Anopress device have been calculated by this study. The Anopress appears to be a safe and well tolerated way of measuring pressures from the entire anal canal. Further comparisons with other standard and commonly used manometry tests are, however, required to verify its reliability.
More Related Videos
Related Concept Videos
Psychosexual Stages of Personality: Anal
Cable Subjected to Its Own Weight
A generalized loading function is employed to analyze a cable subjected to its own weight. This function considers the force acting along the cable's arc length rather than its projected length, providing a more accurate...
Cable Subjected to Concentrated Loads
Cable Subjected to a Distributed Load
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...