Use of porous monoblock patella component should avoid for patient with patella baja
Takao Kaneko1, Norihiko Kono1, Yuta Mochizuki1
1Department of Orthopedic Surgery, Toho University School of Medicine, Tokyo, Japan.
Background:
Although many studies have evaluated the success of porous tantalum component in primary and revision cementless total knee arthroplasty (TKA) cases, few studies have reported the breakage of porous tantalum monoblock patella component (PTMP). The purpose of this study was to investigate the radiographic outcomes of breakage of PTMP at short-term follow up.
Methods:
This was a retrospective study of 49 consecutive knees in 43 patients who underwent TKA surgery between September 2012 and March 2014. Bone marrow contents/tissue volumes (BMC/TV. mg/cm3) were evaluated using 2-dimensional osteomorphometry software with 2D- multi-detector-row computed tomography (2D-MDCT) to measure fixation of the bone-prosthesis interface with patella at 6, 12, and 24 months after surgery. Clinical follow up was obtained by reviewing each patient at orthopedic record.
Results:
We experienced a case that resulted in breakage of PTMP without traumatic episode at 26 months after surgery. Relative changes of Bone Mineral Contents per Tissue Volume. (BMC/TV mg/cm3) at ROI. 1 (superior border of the patella) and ROI. 2 (peg of patella) were significantly higher than ROI.3 (inferior border of patella) at 6, 12 and 24 months after surgery (p < 0.001. p < 0.01). Patient with breakage of PTMP has patella baja (Insall- Salvati ratio: 0.72), and the relative change of BMC/TV at ROI.1 and 2 for patients who experienced a breakage of PTMP was higher than any other patients.
Conclusion:
The present study revealed that the use of PTMP should be avoided for patients with patella baja.
Related Concept Videos
Bones of the Lower Limb: Femur and Patella
Frustration and Conflict: Avoidance-Avoidance, Double-Approach Avoidance
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Components of Language
Personality Disorders: Narcissistic and Avoidant
Characteristics of Narcissistic Personality Disorder
Narcissistic individuals exhibit an inflated sense of self-importance and an excessive need for admiration. They are often...
Avoidance Learning and Learned Helplessness
Avoidance learning occurs when an organism learns that a specific behavior can prevent an unpleasant outcome. For example, a student who receives a bad grade may start studying harder to avoid future poor grades. This behavior persists even when the negative outcome is no longer present. Avoidance learning is powerful because it maintains behavior in the absence of the...