Determining the interchangeability of KaVo PROTAR semi-adjustable articulators
Quintessence International (Berlin, Germany : 1985)
|June 9, 2018
Summary
Most KaVo PROTARevo articulators are not interchangeable, potentially impacting dental restoration accuracy. For precise outcomes, consistently use the same articulator throughout the clinical and laboratory processes.
Area of Science:
- Dental materials science
- Prosthodontics
- Biomaterials engineering
Background:
- Interchangeable articulators are vital for accurate prosthetic restorations.
- A lack of interchangeability can compromise the precision of occlusal relationships.
- This study focuses on the interchangeability of KaVo PROTARevo semi-adjustable articulators.
Purpose of the Study:
- To evaluate the interchangeability of KaVo PROTARevo semi-adjustable articulators.
- To determine if these articulators meet the criteria for precise clinical outcomes.
- To assess the impact of articulator variability on prosthetic restoration accuracy.
Main Methods:
- Utilized KaVo PROTARevo semi-adjustable articulators in regular clinical use.
- Transferred identical casts between articulators to assess dimensional consistency.
- Measured distances between casts using digital photography (sagittal and frontal views) analyzed by software.
- Assessed inter-examiner reliability for measurement consistency.
Main Results:
- High inter-examiner reliability was observed in the measurements.
- Only 27 out of 231 (approximately 11.7%) articulator pairs met the interchangeability criterion (<166 µm).
- The majority of articulator pairs exceeded the 166 µm threshold in at least one measured dimension.
Conclusions:
- Most tested KaVo PROTARevo articulators do not meet the 166-µm interchangeability standard.
- Significant variability exists among these articulators, potentially affecting restoration accuracy.
- It is recommended to use the same articulator consistently from clinical evaluation to laboratory fabrication to ensure accuracy.
Related Concept Videos
Protein Complexes with Interchangeable Parts
2.9K
Groups of proteins may form a complex where each protein in this complex has a different role in the overall execution of the complex’s function. Often some of the proteins in the complex can be replaced by a closely related variant to give a complex that contains many of the same components yet is functionally distinct.
The SCF ubiquitin ligase is a protein complex of five individual proteins. This complex attaches ubiquitin to other target proteins to mark them for degradation. In order...
The SCF ubiquitin ligase is a protein complex of five individual proteins. This complex attaches ubiquitin to other target proteins to mark them for degradation. In order...
2.9K
Protein Complexes with Interchangeable Parts
2.1K
2.1K
Articulations of the Vertebral Column
3.2K
In addition to being held together by the intervertebral discs, adjacent vertebrae also articulate with each other at synovial joints formed between the superior and inferior articular processes called zygapophysial joints (facet joints). These are plane joints that provide for only limited motions between the vertebrae. The orientation of the articular processes at these joints varies in different regions of the vertebral column and serves to determine the types of motions available in each...
3.2K
The Anchoring-and-Adjustment Heuristic
7.8K
In order to make good decisions, we use our knowledge and our reasoning. Often, this knowledge and reasoning is sound and solid. However, sometimes, we are swayed by biases or by others manipulating a situation. For example, let’s say you and three friends wanted to rent a house and had a combined target budget of $1,600. The realtor shows you only very run-down houses for $1,600 and then shows you a very nice house for $2,000. Might you ask each person to pay more in rent to get the...
7.8K
Adjusting a Traverse
387
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
387
Drug Products: Biologics, Biosimilars and Interchangeables
279
Body:Biologics, derived from living sources such as humans, animals, or microorganisms, represent a significant category of pharmaceuticals. These complex molecules, developed through advanced biotechnological methods or purified from natural sources, include essential medical treatments like insulin and growth hormones. The complexity of biologics arises from their large molecular structures and the intricate processes required for their production, making them distinct from conventional...
279