Related Experiment Video
Updated: Feb 9, 2026

Snap Chip for Cross-reactivity-free and Spotter-free Multiplexed Sandwich Immunoassays
Published on: November 13, 2017
The immune complex transfer enzyme immunoassay: Mechanism of improved sensitivity compared with conventional sandwich
Toshihiro Watanabe1, Seiichi Hashida2
1Clinical Innovation, Sysmex Corporation, 4-4-4 Takatsukadai, Nishi-ku, Kobe 651-2271, Japan.
Immune complex transfer enzyme immunoassay (ICT-EIA) is one of the technologies which enables ultrasensitive measurements of protein biomarkers. The ICT-EIA uses two types of beads and sandwich-shaped immune complexes are transferred from the 1st bead to the 2nd bead in the assay. The purpose of the study is to reveal the reason why the ICT-EIA achieves ultrasensitive measurements by making a detailed comparison between conventional sandwich enzyme immunoassay (Sand-EIA) and ICT-EIA. ICT-EIAs for cytokines were developed and the sensitivities were compared with the sandwich EIAs. ICT-EIAs had about 100 times higher sensitivities because of markedly decreased non-specific signals derived from non-specific binding of detection antibody conjugates onto the polystyrene bead. The results have enabled us to show the importance of reducing non-specific signals in EIAs to obtain higher sensitivities. This methodology should be more valuable if combined with a different label detection system such as digital counting or immuno-PCR, which may enable the detection of single target protein molecules in the near future.
Immune complex transfer enzyme immunoassay (ICT-EIA) is one of the technologies which enables ultrasensitive measurements of protein biomarkers. The ICT-EIA uses two types of beads and sandwich-shaped immune complexes are transferred from the 1st bead to the 2nd bead in the assay. The purpose of the study is to reveal the reason why the ICT-EIA achieves ultrasensitive measurements by making a detailed comparison between conventional sandwich enzyme immunoassay (Sand-EIA) and ICT-EIA. ICT-EIAs for cytokines were developed and the sensitivities were compared with the sandwich EIAs. ICT-EIAs had about 100 times higher sensitivities because of markedly decreased non-specific signals derived from non-specific binding of detection antibody conjugates onto the polystyrene bead. The results have enabled us to show the importance of reducing non-specific signals in EIAs to obtain higher sensitivities. This methodology should be more valuable if combined with a different label detection system such as digital counting or immuno-PCR, which may enable the detection of single target protein molecules in the near future.
Related Concept Videos
Enzymes
Enzyme deficiencies can often translate into life-threatening diseases. For example, a genetic abnormality resulting in the deficiency of the enzyme G6PD...
Enzyme Kinetics
Scientists typically study enzyme kinetics with a fixed amount of enzyme in the controlled environment of a test tube. When more reactant, or substrate, is...
Introduction to Mechanisms of Enzyme Catalysis
Transducer Mechanism: Enzyme-Linked Receptors
Major types that are helpful drug targets include:
Enzyme-linked Receptors
Neurotrophin (NT) receptors are a family of RTKs, including trkA, trkB, and trkC (tropomyosin-related kinase) receptors. TrkA is specific for nerve growth factor (NGF), neurotrophin-6, and neurotrophin-7. TrkB binds...
Enzyme Inhibition

