Related Experiment Video
Updated: Feb 9, 2026

Cell-based Assay Protocol for the Prognostic Prediction of Idiopathic Scoliosis Using Cellular Dielectric Spectroscopy
Published on: October 16, 2013
High-frequency, dielectric spectroscopy for the detection of electrophysiological/biophysical differences in
Mohammad Russel1, Marios Sophocleous2, Shan JiaJia1
1School of Food and Environment, Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education, Dalian University of Technology, Panjin, 124221, PR China.
Abstract:
This paper describes a novel technique to quantify and identify bacterial cultures of Bacillus Subtilis (2.10-1.30 × 109 CFU mL-1) and Escherichia Coli (1.60-1.00 × 109 CFU mL-1), in corn oil using dielectric spectroscopy at elevated frequencies of 0.0100-20.0 GHz. This technique is using the electrophysiological/biophysical differences (e.g. gram positive and gram negative) between various bacteria types, as a basis to distinguish between bacteria concentrations and bacteria types. A close-ended, coaxial probe of 20.0 mm long sample-holder was developed and used to calculate the dielectric constant from the measured S parameters of the bacterial cultures, using the Nicolson-Ross-Weir method. This technique shows a linear relationship (r2 ≥ 0.999) between the dielectric constant and the cell concentration, at 16.0 GHz. The sensitivity of the technique is 0.177 × 109 (CFU mL-1)-1 for B. Subtilis (with a size of 10.0 × 1.00 μm), 0.322 × 109 (CFU mL-1)-1 for E. Coli (with a size of 2.00 × 0.500 μm) and 0.913 × 109 (CFU mL-1) -1 for their 1:1 mixture, while the response time is 60.0s. The dependency of dielectric constant on the bacterial cell concentration at a given frequency can be potentially exploited for measuring bacterial concentrations and biophysical differences.
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Capacitor With A Dielectric
Dielectrics are non-conducting materials with no free or loosely bound electrons. When a dielectric is...
Concentration Cells
Consider the following voltaic cell:
Gauss's Law in Dielectrics
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Dielectric Polarization in a Capacitor