[Implementation of Wearable Terminal Used for Dynamic ECG Real-time Monitoring Based on Internet of Things]
Ming Tang1, Jian Yao2, Zekuan Chen2
1College of Biomedical Engineering and Instrumentation Science, Zhejiang University, Hangzhou, 310013. ##Email#.
Abstract:
Electrocardiogram (ECG) detection is a routine and effective cardiac problem detection project. Traditional electrocardiogram detection has limitations in cardiac arrhythmia and other heart disease detection and diagnosis, such as effectiveness, real-time and so on. Based on the advanced mobile networking and wearable design concept, this paper designs and implements a dynamic ECG real-time monitoring system with low power embedded system and Bluetooth 4.0 wireless communication. Its main functions include 24-hour dynamic ECG signal real-time acquisition, processing, wireless communication, display and storage, real-time analysis of typical arrhythmia, recording and alarm, professional doctors real-time reading and diagnosis, dynamic ECG sharing and cloud platform automatic analysis and diagnosis. Both the physiological signal generator and the actual patient's wear test showed that the design and function of the wearable dynamic ECG real-time monitoring terminal based on the mobile networking could meet and apply to the patients with cardiac monitoring needs in the house, hospital, nursing home, outdoor and many other places.
More Related Videos
Related Concept Videos
Termination of Translation
Termination of Translation
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...