Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Standard Electrode Potentials03:02

Standard Electrode Potentials

50.4K
On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
50.4K
Electrodes: Overview01:17

Electrodes: Overview

2.7K
 Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
2.7K
The Fossil Record02:56

The Fossil Record

27.5K
The fossil record documents only a small fraction of all organisms that have ever inhabited Earth. Fossilization is a rare process, and most organisms never become fossils. Moreover, the fossil record only exhibits fossils that have been discovered. Nevertheless, sedimentary rock fossils of long-lived, abundant, hard-bodied organisms dominate the fossil record. These fossils offer valuable information, such as an organism's physical form, behavior, and age. Studying the fossil record helps...
27.5K
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

2.1K
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.1K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

1.8K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.8K
Data Reporting and Recording01:24

Data Reporting and Recording

5.5K
Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Effects of ethanol on non-invasively recorded cerebellar, cerebral, and postural responses to axial perturbation: A case study.

Physiological reports·2026
Same author

Feasibility of decoding cerebellar movement-related potentials for brain-computer interface applications.

Journal of neural engineering·2025
Same author

Selective facilitation of short latency postural reflexes by instability.

Experimental brain research·2025
Same author

Distinct movement related changes in EEG and ECeG power during finger and foot movement.

Neuroscience letters·2025
Same author

Topical review: Ocular surface abnormalities in neurodegenerative disorders.

Optometry and vision science : official publication of the American Academy of Optometry·2025
Same author

Video head impulse gain is impaired in myotonic dystrophy types 1 and 2.

European journal of neurology·2024

Related Experiment Video

Updated: Feb 9, 2026

Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor
06:19

Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor

Published on: January 12, 2018

9.5K

The human electrocerebellogram (ECeG) recorded non-invasively using scalp electrodes.

Neil P M Todd1, Sendhil Govender2, James G Colebatch2

  • 1Department of Psychology, University of Exeter, Exeter, EX4 4QC, UK.

Neuroscience Letters
|June 11, 2018
PubMed
Summary

Researchers have developed a non-invasive method to record the electrocerebellogram (ECeG), which measures cerebellar activity using surface electrodes. This technique shows promise for understanding cerebellar function and clinical applications.

Keywords:
CerebellumElectrocerebellogram (ECeG)Vection

More Related Videos

Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans
08:25

Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans

Published on: May 19, 2016

11.3K
Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
11:25

Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding

Published on: July 26, 2013

44.1K

Related Experiment Videos

Last Updated: Feb 9, 2026

Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor
06:19

Visual Evoked Potential Recordings in Mice Using a Dry Non-invasive Multi-channel Scalp EEG Sensor

Published on: January 12, 2018

9.5K
Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans
08:25

Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans

Published on: May 19, 2016

11.3K
Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding
11:25

Simultaneous Scalp Electroencephalography EEG, Electromyography EMG, and Whole-body Segmental Inertial Recording for Multi-modal Neural Decoding

Published on: July 26, 2013

44.1K

Area of Science:

  • Neuroscience
  • Electrophysiology
  • Cerebellar Research

Background:

  • The electrocerebellogram (ECeG) reflects cerebellar cortical local field potentials (LFPs) with high-frequency components.
  • Current methods for ECeG recording are invasive, limiting clinical application.
  • A non-invasive method for ECeG recording in humans remains elusive.

Purpose of the Study:

  • To investigate the feasibility of non-invasively recording high-frequency power characteristic of the ECeG using surface electrodes.
  • To compare ECeG recordings with standard electroencephalogram (EEG) and electrooculogram (EOG) locations.
  • To assess the impact of visual motion stimulation on ECeG activity.

Main Methods:

  • Continuous electrical recordings were made using surface electrodes placed over the posterior fossa (CB location) in six subjects.
  • Recordings were compared between baseline conditions and during visual motion stimulation.
  • Recordings at posterior fossa sites were contrasted with standard 10/20 locations (C3/4, O1/2) and splenius muscle controls.

Main Results:

  • High-frequency power (ultra-gamma and very high frequency bands) was significantly greater over the posterior fossa compared to occipital or central leads under baseline conditions.
  • Visual motion stimulation effectively increased high-frequency power in posterior fossa electrodes (beta and gamma bands).
  • Myogenic contamination was ruled out through control recordings over splenius muscles.

Conclusions:

  • The human ECeG can be recorded non-invasively using surface electrodes placed over the posterior fossa.
  • This non-invasive ECeG recording method shows potential for both understanding cerebellar function and clinical applications.
  • Visual motion stimulation is a viable method to modulate and enhance ECeG signals.