Development and validation of a 3D-printed neuronavigation headset for therapeutic brain stimulation
Farrokh Mansouri1, Arsalan Mir-Moghtadaei, Vanathy Niranjan
1Institute of Biomaterial and Biomedical Engineering, University of Toronto, Toronto, Canada.
Background:
Accurate neuronavigation is essential for optimal outcomes in therapeutic brain stimulation. MRI-guided neuronavigation, the current gold standard, requires access to MRI and frameless stereotaxic equipment, which is not available in all settings. Scalp-based heuristics depend on operator skill, with variable reproducibility across operators and sessions. An intermediate solution would offer superior reproducibility and ease-of-use to scalp measurements, without requiring MRI and frameless stereotaxy.
Objective:
We present and assess a novel neuronavigation method using commercially-available, inexpensive 3D head scanning, computer-aided design, and 3D-printing tools to fabricate form-fitted headsets for individuals that hold a stimulator, such as an rTMS coil, in the desired position over the scalp.
Methods:
20 individuals underwent scanning for fabrication of individualized headsets designed for rTMS of the left dorsolateral prefrontal cortex (DLPFC). An experienced operator then performed three trials per participant of three neuronavigation methods: MRI-guided, scalp-measurement (BeamF3 method), and headset placement, and marked the sites obtained. Accuracy (versus MRI-guidance) and reproducibility were measured for each trial of each method.
Results:
Within-subject accuracy (against a gold-standard centroid of three MRI-guided localizations) for MRI-guided, scalp-measurement, and headset methods was 3.7 ± 1.6 mm, 14.8 ± 7.1 mm, and 9.7 ± 5.2 mm respectively, with headsets significantly more accurate (M = 5.1, p = 0.008) than scalp-measurement methods. Within-subject reproducibility (against the centroid of 3 localizations in the same modality) was 3.7 ± 1.6 mm (MRI), 4.2 ± 1.4 (scalp-measurement), and 1.4 ± 0.7 mm (headset), with headsets achieving significantly better reproducibility than either other method (p < 0.0001).
Conclusions:
3D-printed headsets may offer good accuracy, superior reproducibility and greater ease-of-use for stimulator placement over DLPFC, in settings where MRI-guidance is impractical.
Related Concept Videos
Reliability and Validity
In Vitro Drug Release Testing: Overview, Development and Validation
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Therapeutic Index