Related Experiment Video
Updated: Feb 9, 2026

Modeling Myotonic Dystrophy 1 in C2C12 Myoblast Cells
Published on: July 29, 2016
Ankle Strength Impairments in Myotonic Dystrophy Type 1: A Five-Year Follow-up
Luc J Hébert1,2,3, Christophe Vial4,5, Jean-Yves Hogrel6
1Department of Rehabilitation, Faculty of Medicine, Laval University, QC, Canada.
Background:
In Myotonic Dystrophy type 1 (DM1) patients, ankle muscles are affected early and this impairment is reported to be a good biological marker for longitudinal studies.
Objective:
To characterize the ankle dorsiflexion (DF) and eversion (EV) maximal isometric muscle strength changes in adult DM1 patients over 5 years using a standardized handheld dynamometer protocol and the Myoankle method, compare the changes measured with both methods and to the standard error of measurement, and verify the relationship between ankle muscle strength and gait performance.
Methods:
The maximal isometric muscle strength of ankle DF and EV in DM1 patients from Quebec and Lyon was assessed at baseline, 18, 36 and 60 months using a handheld dynamometer (HHD) protocol and the MyoAnkle method.
Results:
There was a decrease of torque in DF/EV of 36.0% /31.3% and 27.7% /35.5% for the Quebec and Lyon cohorts respectively (p≤0.01), but not in a linear way. In most cases (82.5%), the changes observed were greater than the standard error of measurement. DF torque measures taken by the two methods (HHD and MyoAnkle) were highly correlated (rp = 0.97-0.98, p < 0.001).
Conclusion:
Muscle strength ankle impairments are clinically meaningful in DM1 and can be accurately monitored using quantitative testing to measure the efficacy of therapeutic trials.
Related Concept Videos
Ankle Joint
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
Relative Strengths of Conjugate Acid-Base Pairs
Satellite Stem Cells and Muscular Dystrophy

