Related Experiment Video
Updated: Feb 9, 2026

Author Spotlight: Self-Assessment Protocol for Predicting Psoriatic Arthritis in Psoriasis Patients
Published on: March 1, 2024
A new modified neuroendoscope technology to remove severe intraventricular haematoma
Bo Du1, Ai-Jun Shan1, Yu-Ping Peng2
1a Department of Emergency , Shenzhen People's Hospital, The Second Affiliated Hospital of Jinan University , Shenzhen , China.
Background:
Minimally invasive endoscopic haematoma evacuation is widely used in the treatment of intraventricular haemorrhage. However, its technique still has room for improvement. A new modified neuroendoscope technology (MNT) was used in this study and we explored its safety and efficacy in the treatment of severe acute intraventricular haemorrhage by comparing it with extraventricular drainage plus urokinase thrombolytic (EVD + UT) therapy.
Methods:
The following parameters were compared between the MNT group and the control group: incision design, operation time, ICU monitoring time, ventricular drainage tube (VDT) placement time, post-operative drainage tube obstruction (PDTO) rate, post-operative complications rate, 6-month mortality and Glasgow Outcome Scale (GOS).
Results:
A total of 85 patients were enrolled. The ICU monitoring times, VDT placement times, PDTO rate were shorter in the MNT group. Multivariable logistic regression identified that good medium-term outcome (GOS scores 4-5) was significantly associated with MNT applied (OR 1.017, 95% CI 1.005-1.029, p = 0.008), age under 65 years (OR 4.223, 95% CI, 1.322-17.109, p = 0.034) and pre-operation GCS scores more than 10 (OR 3.427, 95% CI 1.048-11.205, p = 0.040).
Conclusion:
MNT surgery for severe intraventricular haematoma evacuation is a safe and efficient new surgical option. This technique is minimally invasive and may be helpful to provide good outcomes for selected patients.
Related Concept Videos
Hybridoma Technology
Hybridoma Selection
Commonly used fusion techniques — electroporation,...
Health Information Technology and Healthcare Information System
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Modified Boxplots
However, the box plot does not tell the reader about outliers - values that lie far from the center of the data. We can modify the standard box and whisker plot to identify the outliers and visualize the actual spread of the data in a sample.
Initially, we calculate the adjusted...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Antiasthma Drugs: Leukotriene Modifiers
Leukotriene modifiers work through two distinct mechanisms:
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis