Related Experiment Video
Updated: Feb 9, 2026

Evaluation of the Interplay Between the Complement Protein C1q and Hyaluronic Acid in Promoting Cell Adhesion
Published on: June 15, 2019
Comparison of the Microstructures and Properties of Different Microcannulas for Hyaluronic Acid Injection
Kelun Wu1, Li Xie1, Muyao Wang1
1From the State Key Laboratory of Oral Diseases, the Department of Oral and Maxillofacial Surgery, and the National Engineering Laboratory for Oral Regenerative Medicine, Sichuan University, West China College of Stomatology; and the First People's Hospital of Liangshan Yi Autonomous Prefecture.
Background:
Microcannulas are used for hyaluronic acid and other filler injections and reduce the side effects and complications. There are several microcannulas and the differences between microcannulas have not been carefully investigated. The purpose of this study was to compare the microstructures and properties of different microcannulas by several trials and provide guidance for clinical application.
Methods:
Nine types of microcannulas from different manufacturers were chosen. Scanning electron microscopy was used to obtain high-definition images of microstructures, chemical composition analyzers were used to test the chemical composition of the tips, and a universal testing machine was used to measure mechanical properties. The injection speed test recorded the time spent for the weight to push hyaluronic acid out of microcannulas. The vessel piercing force test was conducted to simulate the process of puncturing the vessels in vitro.
Results:
The scanning electron microscopic images showed the tip shapes and inner surfaces that may relate to the characteristics. The chemical composition of most microcannulas met the American Society for Testing and Materials standards basically. The mechanical properties were obviously different. The results of the injection speed test were discrepant more than seven times. The vessel piercing test showed which microcannula was the most difficult and easiest to puncture the aorta.
Conclusions:
The results indicated that there are significant differences between different microcannulas. The differences are instructive to physicians for selecting suitable microcannulas to improve the injection effect and reduce discomfort and complications.
Clinical Question/Level Of Evidence:
Therapeutic, V.
Related Concept Videos
Physical Properties of Carboxylic Acids
Physical Properties of Carboxylic Acid Derivatives
Among the carboxylic acid derivatives, the boiling points of acid chlorides and esters are very similar and are the lowest in the series. Acid anhydrides have slightly higher boiling...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Physical and Chemical Properties of Matter
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons

